SCHRACK
Other Data
Terminal type
standard version PCB -THT
2)
reinforced sealed version PCB -THT, plug-in
reflow version PCB -THR
Mounting distance ≥0mm
Weight 10g
Resistance to soldering heat
THT, IEC 60068-2-20 RTII 270°C/10s
THR: reflow version forced gas convection
3)
or vapour phase
4)
temperature profile according EN61730
Packaging/unit tube/20 pcs., box/500 pcs.
2) The use of foaming flux is not permitted.
3) Infrared heating not allowed
4) Recommended fluid LS-230
5) only for reflow version 2,5mm
6) only for reflow version 15,7 +0,3/-0mm
Accessories
For details see datasheet
Accessories Industrial Power Relay RT
NOTE: indicated contact ratings and electrical endurance data for direct
wiring of relays (according IEC 61810-1); for relays mounted on sockets
deratings may apply.
General Purpose Relays
PCB Relays
Power PCB Relay RZ (Continued)
Mechanical endurance >10x10
6
operations
Coil Data
Coil voltage range 3 to 48VDC
Operative range, IEC 61810 2
Coil insulation system according UL1446 class F
Coil versions, DC coil
Coil Rated Operate Release Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% mW
D003 3 2.1 0.3 22 410
D005 5 3.5 0.5 60 420
D006 6 4.2 0.6 90 400
D009 9 6.3 0.9 200 400
D012 12 8.4 1.2 360 400
D015 15 10.5 1.5 562 410
D024 24 16.8 2.4 1440 400
D048 48 33.6 4.8 5730 400
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Insulation Data
Initial dielectric strength
between open contacts 1000V
rms
between contact and coil 5000V
rms
Clearance/creepage
between contact and coil ≥10/10mm
Material group of insulation parts IIIa
Tracking index of relay base PTI250V
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Resistance to heat and fire
standard and reflow cover version according EN 60335-1, par.30
Ambient temperature
standard version -40 to 85°C
Category of environmental protection
IEC 61810 RTII - flux proof
Vibration resistance (functional), 30 to 500Hz
closing form A contact >15g
opening form A contact >20g
opening form B contact >5g
Shock resistance (destructive) 100g
Dimensions
12 A, pinning 3.5 mm 12A, 16 A, pinning 5 mm
S0557-AB S0557-AA
5) only for reflow version 2,5mm
6) only for reflow version 15,7 +0,3/-0mm
5) only for reflow version 2,5mm
6) only for reflow version 15,7 +0,3/-0mm
6)
5) 5)
6)