REQUIREMENTS:
2.0 DESIGN AND CONSTRUCTION:
Product shall comply with the design, construction and physical dimensions specified in the
applicable product drawing.
2.1 MATERIALS:
Components
Material
Finish, for
contacts only
Contacts
Receptacle contacts: Phosphor Bronze
Tab contacts: Brass
PreTin plated
Housings / Sec. Lock PA 6.6, Glassfiber filled /
Radial Sealing / Single wire seals
Liquid silicone rubber /
2.2 RATINGS:
A. Current Rating : 14A max. with 1,5 mm² wire
B. Temperature Rating: -40°C to +125°C including the temperature increasing due to
working current flow
C. Maximum Operating Voltage: 24 Vd.c.. For application at higher voltage please
contact Tyco Electronics.
D. Protection Degree: IP 67, IPX6K, IP X9K according to IEC 529 and to DIN 40050,
Part 9.
2.3 QUALITY ASSURANCE PROVISION:
A. Sample preparation
:
The test samples to be used for the tests shall be prepared by randomly selecting from
the current production, and the contact crimped in accordance with the Application
Specification 114-20045. No sample shall be reused, unless otherwise specified.
B. Test Environment:
All the tests shall be performed under any combination of the following test conditions,
unless otherwise specified.
Room temperature: 23 ± 2°C
Relative Humidity: 45÷70%
Atmospheric Pressure: 860÷1060 mbar