Information

Product Specification
108-5262
Rev. C6 11 of 14
Para.
Test Items Requirements Procedures
Must meet the specified
requirements after testing in
the sequence specified in Fig.9.
Subject mated contact to test
current of the intensity obtained
by Fig.6 applied for 300 cycles
intermittently 45 minutes ON, 15
minutes OFF to the series wired
contacts.
3.5.28
Current Cycling
Wire Size
(mm
2
)
Test Current
(DC A)
No. of Positions
Reduction
Coefficient
0.2
0.3
0.5
0.85
1.25
7
9
11
14.5
18.5
1
23
45
68
912
1
0.75
0.6
0.55
0.5
Fig.6
Note: Applying current is obtained by calculation by multiplying
the current value of applicable wire size and the reduction
coefficient according to the number of contact loading of the
connector.
3.5.29
Vibration Sinusoidal
High Frequency
No electrical discontinuity
greater than 1 microsecond
shall occur.
Fig.9.
Subject mated connectors to
20-200 Hz traversed in 3 minutes
with 44m/s
2
(4.5G) accelerated
velocity; 2 hours each for “X” and
“Y” axis, and 4 hours for “Z” axis.
Monitor circuit for electrical
discontinuity greater than 1μsec.
taking place in the series-wired
contacts.