Information

Product Specification
108-5262
Rev. C6 14 of 14
5. Quality Assurance Provisions:
5.1 Test Conditions:
Unless otherwise specified all the tests shall be performed in any combination of the following
test conditions.
Temperature
Relative Humidity
Atmospheric Pressure
1535
4575
86.7107KPa
650800mmHg
Fig.10
5.2 Sample Preparation:
5.2.1 Samples:
The samples to be employed for the tests shall be prepared in accordance with 114-5082,
TE Application Specification, Crimping .070 & .250 Series Contact for AMP-ECONOSEAL “J”
Mark
Connector, by using the wires specified in Table 8. No sample shall be reused, unless
otherwise specified.
5.2.2 Number of Samples:
The number of contact and connector samples shall be consisting of more than 10 pieces
contacts for testing contact, and more than 2 sets of connectors for testing connector.
5.2.3 Wires Used:
The wires to be employed for the tests shall be the ones specified in Table 8.
Wire Size
Wire Strand
Composition
Cross-Sectional
Area
Nominal
AWG
Strand
Diameter
(mm)
Number of
Strands
mm
2
CMA
Remarks
0.2
0.3
0.5
0.85
1.25
#24
#22
#20
#18
#16
0.20
0.26
0.32
0.32
0.32
7
7
7
11
16
0.22
0.37
0.56
0.88
1.29
434
733
1111
1746
2540
Wires AV and
thin wires (AVS)
for automobiles.
JIS C 3406
Fig.11
6.1 Crimping and Assembly Processing:
In order to maintain reliable termination performance of housing and contacts, crimping
contact shall be performed in accordance with 114-5082, TE Application Specification,
Crimping .070 & .250 Series Contact for AMP-ECONOSEAL “J” Mark
Connector.
Manufacturing harness and extracting contacts shall be performed in accordance with
Customer Manual 412-5325, AMP-ECONOSEAL “J” Mark
Connectors.