Information

408- 9381
Rev C2 of 2
CONTACT WIRE SIZE INSULATION
PIN CONTACT NUMBER SOCKET CONTACT NUMBER
C
O
N
T
A
C
T
TYPE
W
I
R
E
S
I
Z
E
RANGE, AWG
I
N
S
U
L
A
T
I
O
N
DIA. RANGE
STRIP LP STRIP LP
High Density 22
DF
28 to 22
0.76--1.02
[.030--.040]
1658670--1, --3 1658670--2, --4 1658686--1, --3 1658686--2, --4
Figure 2
3.3. Contact Insertion and Extract ion
Insertion/Extraction Tool 91285--1 is designed for
the installation and removal of contacts used in
AMPLIMITE HDP--22 Connectors. For detailed
information on use of the tool, refer to Instruction
Sheet 408--9404 which is packaged with the tool.
After contacts have been crimped to wires, insert
contacts into the BACK of the connector until they
snap--lock into place. Pull back lightly on each wire to
make sure that the contact is fully seated. If all
cavities are not used, TE suggests that contacts be
evenly distributed throughout the connector.
Damaged product should not be used. If
damaged products are evident, they should be
replaced with new ones.
4. HARDWARE
AMPLIMITE HDP--22 plugs and receptacles will
accept all AMPLIMITE HD--22 and HD--20 external
hardware designed for the same shell size. For
detailed information regarding the description and
application of the hardware, refer to Catalog 82068
and Application Specification 114--10001.
5. PANEL CUT OUT
Refer to Application Specification 114--10001 for
cutout dimensions and clearance requirements
for AMPLIMITE HDP--22 Connectors.
AMPLIMITE HDP--22 connectors are designed for
rack and panel applications. Plugs are mounted in the
panel, and receptacles in the rack. Before making the
panel cutout, determine the shell size of the
connector (number of positions and rows), mounting
requirements (FRONT or REAR), and the type of
locking device (cable clamp or slide latch) for the
application. Then, using the appropriate dimensions,
make the panel cutout.
6. REVISION SUMMARY
Revisions to this instruction sheet include:
S Updated document to corporate requirements.
NOTE
i
NOTE
i
NOTE
i