VNC (Virtual Network Computing)
You can operate the system on a computer by displaying
the screen which is displayed on this units LCD on the
computer using VNC Viewer Application.
You can operate the following using a mouse on the VNC
Viewer Application.
Left click of the mouse : Operates in the same way as touching
the LCD of this unit.
Mouse wheel click : Operates in the same way as the ENTER
key of this unit.
Mouse wheel rotate : Operates in the same way as the DATA
dial of this unit.
Mouse wheel press
and rotate
: Operates in coarse settings in the same
way as when you press and rotate the
DATA dial of this unit (COARSE mode op-
eration).
You can perform the following operations using the
computer keyboard with the VNC Viewer Application
active.
F1 to F12 key : Operate in the same way as an external
keyboard connected with this unit.
See “Section 12 Other functions” Opera-
tions using the computer keyboard –Key-
board Operation in the Operation Manual
of this unit.
HOME key : Operates in the same way as the HOME
key of this unit and displays the HOME
screen. Press the End key while hold-
ing the HOME key to display the
LOCK
SETUP
screen.
End key : Operates in the same way as the MENU
key of this unit and displays the
MENU
screen. Press the End key while hold-
ing the HOME key to display the
LOCK
SETUP
screen.
PageDown : Operates in the same way as the PROJECT
key of this unit and displays the
PROJ-
ECT
screen.
Cursor 2 key : Operates in the same way as rotating the
DATA dial of this unit clockwise.
when editing parameter values, or scrolls
the list up when the screen shows a list.
Cursor x key : Operates in the same way as rotating the
DATA dial of this unit anti-clockwise.
when editing parameter values, or scrolls
the list down when the screen shows a list.
Character input keys : Input the characters while this unit dis-
plays the keyboard screen.
Setting values necessary to connect with VNC
Setting values necessary to connect VNC Viewer Appli-
cation with this unit are as follows:
IP Address : The IP Address of this unit is shown in IP Ad-
dress on the
ETHERNET
page of the
REMOTE
SETUP
screen.
Password : The default password is “HS-2”.
Distinguishes between capital letters and small
letters.
You can change the password using the
Password [Change ]
button on the
ETHERNET
page of the
REMOTE SETUP
screen.
NOTE
Only one active VNC connection is allowed.
If
EXTERNAL Control
" on the
LOCK SETU
P screen
is set to
LOC
K, display in the VNC Viewer Application
is possible, but mouse and keyboard interaction is
ignored.
If you change any setting on the E
THERNET
page on
the
REMOTE SETUP
screen while a VNC connection is
active, that VNC session will be disconnected.
Please consult with TASCAM Customer Support for
information about VNC Viewer Applications that have
been tested with this unit.
VNC Viewer Application response will slow down when
a file is being transferred by FTP, or at high system Fs
rates (88.2kHz/96kHz/176.4kHz/192kHz)
Audio Signal Input and Output
settings (AUDIO I/O)
Input and Output Audio signal settings can be changed
here.
The
AUDIO I/O
screen has two pages:
INPUT
and
OUTPUT
.
Touch the tabs at the bottom of the screen to open the
corresponding page.
INPUT page
Make input settings on this page.
INPUT SOURCE
You can set the input source. Select analog XLR input,
analog RCA input or digital input.
Setting buttons:
Analog XLR
(Default),
Analog RCA
,
Digital X
(“
X
stands for either
AES/EBU
or
S/PDIF
)
DIGITAL SOURCE
You can select the digital input source.
Setting buttons:
AES/EBU
(Default),
S/DIF
Fs CONVERT
Turn the sampling rate converter ON or OFF (default) for
each pair of inputs.