Technical Specifications
PRODUCT SPECIFICATIONS
Series: M5XXX
Wearlayer: Urethane (Low Gloss)
Nominal Wearlayer Thickness: .010” (0.25mm)
Nominal Total Thickness: .080” (2.0mm)
Widths: 12’ (3.6m)
Maximum Roll Size (Sq. Yds.): 148 (123 m
2
)
Weight per Sq. Yd. (Lbs.): 3.1 (1.4 kg)
ASTM F-970 Static Load Limit: 75 lbs/in
2
(34 kg)
ASTM F 1303: Type I, Grade 3, Class C
HUD/FHA Minimum Property Standards: Meets Wearlayer Thickness Requirement
CERTIFIED asthma & allergy friendly™ by the Asthma and Allergy Foundation of America (AAFA)
INSTALLATION
Use: Residential.
Installation System: Glueless or Full Spread.
Location: Below, on and above grade concrete, approved underlayment grade plywood and approved existing floors.
Adhesive: Tarkett QBond-One
™
Adhesive.
Adhesive Application: Releasable - Apply adhesive evenly over substrate using a medium nap paint roller. Allow adhesive to dry until it is tacky
to the touch.
Permanent - Apply adhesive with a 1/32” deep x 1/16” wide x 1/32” apart notched trowel. Place flooring into adhesive
immediately after application. When installing over an existing floor, allow adhesive to dry until it is tacky to the touch.
Seam Method: Glueless - Double-cut dry. Use Tarkett S875 Floating Seam Tape under seams on all approved substrates. Tarkett S860
Seam Tape may be used when installing over concrete.
Full Spread (Releasable) - Double-cut. No tape required.
Full Spread (Permanent) - Double-cut dry. Use Tarkett S860 Seam Tape.
Seam Sealer: Tarkett DT-65 Seam Sealer.
• Maintain the work area, flooring and adhesive between 65° F and 100° F (18°C - 38°C) for 48 hours bef ore, during and after installation. Maintain
relative humidity is between 40% and 70%.
• Use only cementitious based patching and leveling compounds.
• Unroll flooring and allow material to relax for 20-30 minutes before fitting.
• When installing using the Glueless Installation System, leave a 1/4” space between flooring and all verticals (walls, pipes, cabinets, etc.).
• Installations subjected to heavy traffic, caster action or requiring net fit must be fully adhered using Tarkett QBond-One
™
.
• When using the full spread application, roll flooring in both directions with a 75-100 lb. (34-45kg) sectional floor roller.
• Protect sealed seams from all traffic for a minimum of 3 hours.
CARE AND MAINTENANCE
• When adhering flooring, do not replace frequently moved furniture or allow heavy traffic for at least 24 hours.
• Never slide furniture or appliances across the floor. Place sheets of plywood over floor when moving furniture and appliances into position.
• Use smooth, hard plastic or metal furniture rests or glides under frequently moved furniture to avoid scratches and indentations.
• Sweep or vacuum to remove loose dirt or debris that can scratch the floor.
• Wash floor with Tarkett SureShine
®
Floor Cleaner or equal neutral floor cleaner. Dilute floor cleaner accordingly.
• Use non staining mats or area rugs at doorways and entranceways to collect excess water, sand, grit and debris.
• Maintain post installation temperature between 55º F and 100º F. Maintain relative humidity between 40% and 70%.
LIMITED WARRANTY (refer to warranty guide for detailed information)
• 10 Year Wear and Manufacturing Defects.
• 10 Year Rip, Tear, Gouge and Indent
• 10 Year Common Household Surface Stain
• 10 Year Moisture Stain (Concrete only)
• 10 Year Underlayment Panel Stain
• 10 Year Traffic/Asphalt Stain
• 10 Year Shoe Scuff
SPECIFICATION
SHEET
Beginnings
™
FiberFloor
®
Sheet Flooring
December 3, 2012