Datasheet
TSH190
Bipolar High Voltage Hall Effect Latch
3/8
Version: B13
Magnetic Specifications
Parameters Test Conditions Min Typ Max Units
Operate Point 10 -- 110 Gauss
Release Point -110 -- -10 Gauss
Hysteresis -- 100 -- Gauss
Note: 1G (Gauss) = 0.1mT (millitesta)
Output Behavior versus Magnetic Pole
DC Operating Parameters: T
A
= -40 to 125
o
C, V
CC
= 4 to 30V
Parameter Package Test condition OUT
North pole
TO-92S B>B
OP
Open
South pole
TO-92S B<B
RP
Low
North pole
SOT-23 B>B
OP
Low
South pole
SOT-23 B<B
RP
Open
TO-92S SOT-23
OUT=Open
(Pull-up Voltage)
OUT=Low
(VDSon)
OUT=Low
(VDSon)
OUT=Open
(Pull-up Voltage)