Datasheet

TS78L00 Series
Taiwan Semiconductor
4 Version: J1801
ELECTRICAL SPECIFICATIONS TS78L09
(V
IN
=15V, I
OUT
=40mA, 0
o
CT
J
125
o
C, C
IN
=0.33µF, C
OUT
=0.1µF, unless otherwise noted)
PARAMETER
CONDITIONS
SYMBOL
MIN
TYP
MAX
UNIT
Output voltage
T
J
=25
o
C
V
OUT
8.65
9
9.36
V
11.5VVin23V,
5mAI
OUT
100mA
8.57
9
9.45
V
Line Regulation
T
J
=25
o
C
11.5VVin23V
I
OUT
=40mA
REG
LINE
--
90
180
mV
Load Regulation
T
J
=25
o
C
5mAI
OUT
100mA
REG
LOAD
--
30
90
mV
5mAI
OUT
40mA
--
15
45
Quiescent Current
I
OUT
=0, T
J
=25
o
C
I
Q
--
3
6
mA
Quiescent Current Change
11.5VVin23V
ΔI
Q
--
--
1.5
mA
5mAI
OUT
40mA
--
--
0.1
Output Noise Voltage
10Hzf100KHz, T
J
=25
o
C
V
N
--
60
--
µV
Ripple Rejection Ratio
F=120Hz, 11.5VVin23V
RR
37
57
--
dB
Voltage Drop
I
OUT
=100mA, T
J
=25
o
C
V
DROP
--
1.7
--
V
Peak Output Current
T
J
=25
o
C
Io peak
--
0.15
--
A
Temperature Coefficient of
Output Voltage
I
OUT
=5mA, 0
o
CT
J
150
o
C
ΔV
OUT
/ ΔT
J
--
-0.9
--
mV/
o
C
ELECTRICAL SPECIFICATIONS TS78L12
(V
IN
=19V, I
OUT
=40mA, 0
o
CT
J
125
o
C, C
IN
=0.33µF, C
OUT
=0.1µF, unless otherwise noted)
PARAMETER
CONDITIONS
SYMBOL
MIN
TYP
MAX
UNIT
Output voltage
T
J
=25
o
C
V
OUT
11.53
12
12.48
V
14.5VVin27V,
5mAI
OUT
100mA
11.42
12
12.60
V
Line Regulation
T
J
=25
o
C
14.5VVin27V
I
OUT
=40mA
REG
LINE
--
120
240
mV
Load Regulation
T
J
=25
o
C
5mAI
OUT
100mA
REG
LOAD
--
40
120
mV
5mAI
OUT
40mA
--
20
60
Quiescent Current
I
OUT
=0, T
J
=25
o
C
I
Q
--
3
6.5
mA
Quiescent Current Change
14.5VVin27V
ΔI
Q
--
--
1.5
mA
5mAI
OUT
40mA
--
--
0.1
Output Noise Voltage
10Hzf100KHz, T
J
=25
o
C
V
N
--
80
--
µV
Ripple Rejection Ratio
F=120Hz, 14.5VVin27V
RR
37
42
--
dB
Voltage Drop
I
OUT
=100mA, T
J
=25
o
C
V
DROP
--
1.7
--
V
Peak Output Current
T
J
=25
o
C
Io peak
--
0.15
--
A
Temperature Coefficient of
Output Voltage
I
OUT
=5mA, 0
o
CT
J
150
o
C
ΔV
OUT
/ ΔT
J
--
-1.0
--
mV/
o
C
Note:
1. Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible,
and thermal effects must be taken into account separately
2. This specification applies only for DC power dissipation permitted by absolute maximum ratings.