Installation

6
2. If pipe tee is female, rst apply Te on tape or pipe joint compound to threads of pipe
nipple (not supplied), and thread pipe nipple into female pipe tee. Then thread (gas) no.7
valve onto pipe nipple and tighten.
3. For “Vertical” or “Combination” loop
installations, attach no.5 (male/female elbow)
as shown to no.7 valve with Te on tape or
pipe joint compound.
4. Apply Te on tape or pipe joint compound
to male threads of no.4. Thread no.4 into no.7
valve or no.5 and tighten.
Appliance Side without Quick Disconnect
1. For chosen loop installation, attach
no.6 (female/female elbow) to the male
appliance stub-out with Te on tape or
pipe joint compound.
2. Thread male end of no.4 into no.6
(female elbow) at appliance and tighten.
Appliance Side with Quick Disconnect
1. For chosen loop installation, attach no.5 (female/female elbow) to the male appliance
stub-out with Te on tape or pipe joint compound.
2. Separate no.8 coupling. No.9 nipple (male) half will remain attached to no.4 tting.
No.10 coupling (female) half will remain attached to no.1.
3.Apply Te on Tape or pipe joint compound to threads of no.4 tting. Thread male end of
no.4 into female elbow at appliance and tighten.
4. Reconnect no.8 coupling to nipple.
Finishing
1. Check tightness of all connections and perform leak test.
2. After installation of no.8 Connector, carefully push appliance back to operating
position and check that no.1 is not kinked, overbent, or caught under appliance casters.
Set length of no.11 so no.1 is never fully extended.
3. Af x Orange label “Installation Instruction for Heavy-Duty Gas Connector” to back
of appliance after installation. Af x Yellow label to wall near no.7 or equivalent valve.
Installation:
Safe Safe-T-Link Gas Connectors without SwiveLink Fittings
General
Follow General Step 1 through 5 on page 5.
Review Comparison
See Diagram on following page.
WARNING: No.8 must be oriented so
uid enters no.10 coupling half and
exits no.9 nipple half. Follow ow
direction arrows marked below and on
no.10 itself.
10
Coupling Half
(female)
9
Nipple Half
(male)
Gas Flow Direction
General Instructions