Installation

5
For movable appliance installation (e.g.
appliances factory-equipped with casters),
exing and bending should be limited
to the needs of pulling and pushing
the appliance in and out for cleaning,
maintenance or installation.
Contact with foreign objects or substances
must be avoided.
Choose one of the following three setup
appropriate to your installation of a T&S
Safe-T-Link Gas Hose Connector with
SwiveLink ttings:
Offset
Connector
Appliance
Wall
Installation:
Safe Safe-T-Link Gas Connectors
with SwiveLink Fittings
General
1. Shut the manual gas shut-off valve on
gas manifold line to “OFF”. If there is
no gas shut-off valve, main gas supply
line valve should be turned off. Do not
proceed unless gas is turned off.
2. Carefully read these entire
installation instructions.
3. Location of the two connection points
for gas appliance connectors (the gas
supply line and the equipment stub-
out) can vary greatly. For installations
which result in a sharp bend, a T&S
SwiveLink Gas Connector is ideal.
4. To be able to position gas appliance
as close to the wall as possible, the two
ends of the SwiveLink Gas Connector
should be offset from each other.
5. Each piece of equipment must have
its own approved manual shut-off valve
off the main gas supply line.
Gas Supply Side
1. If pipe tee is already male, apply
Te on tape or pipe joint compound on
pipe threads at gas supply line.
General Instructions