IOM SYSLOOP 70 135 (IOM SL R513 01 S 1GB)
Table Of Contents
- CONTENTS
- 1. GENERAL RECOMMENDATIONS
- 2. INSPECTION AND STORAGE
- 3. WARRANTY
- 4. TECHNICAL SUPPORT AND AFTER-SALES SERVICE HOTLINE
- 5. PRESENTATION
- 6. CONTENTS OF PACKAGE
- 7. DIMENSIONS
- 8. HANDLING
- 9. TECHNICAL SPECIFICATIONS
- 10. INSTALLATION
- 11. DUCTING AND NOISE LEVEL REDUCTION
- 12. HYDRAULIC LINKS
- 13. WIRING DIAGRAM AND LEGEND
- 14. ELECTRICAL CONNECTIONS
- 15. REGULATION
- 16. FINAL TASKS
- 17. STARTING - RECOMMENDATIONS - SETTINGS
- 18. MAINTENANCE AND SERVICING
- 18.1. MAINTENANCE PROCEDURES
- 18.2. FAULT FINDING
- 18.2.1. NEITHER THE FAN NOR THE COMPRESSOR OPERATE
- 18.2.2. VENTILATION (FAN) MODE OPERATES BUT THE COMPRESSOR DOES NOT OPERATE
- 18.2.3. INSUFFICIENT COOLING OR HEATING PRODUCTION
- 18.2.4. INSUFFICIENT WATER FLOW AT THE LEVEL OF THE COAXIAL EXCHANGER.
- 18.2.5. APPEARANCE OF WATER DROPLETS IN THE APPLIANCE
- 18.2.6. APPEARANCE OF ABNORMAL NOISES AND VIBRATIONS IN THE CASING
- 18.3. ALARM CODES
- 19. WARRANTY CLAIM - MATERIAL RETURN PROCEDURE
- 20. ORDERING SERVICE AND SPARE PARTS ORDER
- 21. DISPOSAL
- DIMENSIONS
- REFRIGERANT CIRCUIT DIAGRAM
- WIRING DIAGRAM
- DIMENSIONS
- SCHEMA DU CIRCUIT FRIGORIFIQUE
- SCHEMAS ELECTRIQUES
- ABMESSUNGEN
- KÄLTEKREISLAUFDIAGRAMM
- STROMLAUFPLANS
- DIMENSIONI
- SCHEMA DEL CIRCUITO REFRIGERANTE
- SCHEMA ELETRICO
- DIMENSIONES
- ESQUEMA DEL CIRCUITO FRIGORIFÍCO
- ESQUEMA ELECTRICO
English
7SYSLOOP 70-135
9. TECHNICAL SPECIFICATIONS
9.1. MODELS DESIGNATION
The product plate on the device shows the full model reference number and should be used to check that
the actual unit matches the model ordered. It also provides the following information:
² General information
serial number
year of manufacture
IP index
² Electrical information
supply voltage
maximum operating current
starting current
² Thermodynamic circuit information
type of refrigerant
refrigerant charge in each circuit
Service pressure of refrigeration circuit
refrigeration circuit service temperatures
² Hydraulic circuit information
nominal water ow
maximum water pressure
REP. Description
1
Size
SL70 : SYSLOOP size 70
SL85 : SYSLOOP size 85
SL100 : SYSLOOP size 100
SL110 : SYSLOOP size 110
SL120 : SYSLOOP size 120
SL135 : SYSLOOP size 135
2
Version CO : Cooling only HP : Heat pump
3
Brand SYS : Systemair
4
Fan type EC : Fan with EC motor
5
Air lter Blank : Without lter G2M1 : G2M1 lter
6
Regulation
POL423 : POL423 SIEMENS (Modbus RTU / Bacnet
MSTP)
DISTECH : DISTECH (Bacnet IP)
7
Electric heater
Blank : Without heater
EH3750 : Capacity 3750W
EH4500 : Capacity 4500W
EH5400 : Capacity 5400W
EH6500 : Capacity 6500W
EH7500 : Capacity 7500W
8
Communication
protocol
Blank : Stand Alone MBRT : Modbus RTU
BNMS : Bacnet MSTP
BNIP : Bacnet IP
9
Main switch Blank : Without main switch SECT : Main switch
10
Air outlet S1 : Frontal S2 : Lateral
11
Remote control
Blank : Without remote control RCS : POL822
12
Water valve Blank : Without 2W : two-way valve
13
Option FS : Flow switch
14
Option RS : Room temperature sensor
15
Packaging IP : Individual Packaging GP : Grouped Packaging
SL70 . HP . SYS . EC . G2M1 . POL423 . EH3750 . MBRT . SECT . S1 . RCS . 2W . FS . RS . IP
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15