IOM SYSAQUA R32 70 130 (IOM AQA R32 02 S 1GB)

1/4
Access
Services
Commissioning
Status
Main Menu
1/13
10:40:05
Versions
Scheduling
Load Shedding
NetTune Cascade
Reduced mode
Water Law
Auto changeover
Glycol protection
Communications
Language selection
03.01.2021
Cold OAT protection
Small volume protection
Commissioning
1/4
Access
Services
Commissioning
Status
Main Menu
1/13
10:40:05
Versions
Scheduling
Load Shedding
NetTune Cascade
Reduced mode
Water Law
Auto changeover
Glycol protection
Communications
Language selection
03.01.2021
Cold OAT protection
Small volume protection
Commissioning
1/12
Off
*:*
Off
22:00
On
14:00
Load Shedding
11:00
On
07:00
Off
00:00
Value 6
Time 6
Value 5
Time 5
Value 4
Time 4
Value 3
Time 3
Value 2
Time
Value 1
1
Monday
1/4
Load Shedding
Reduced mode
On
Off
1/3
Tu-Su
Tu-Fr
Mo to
1/10
Off
Off
Off
On
On
On
On
Mo to
Off
On
Exception
Sunday
Saturday
Friday
Thursday
Wednesday
Tuesday
Copy schedule
Monday
Schedule
1/5Alarm history
4
+ Evaporating P. Circuit 1: op. loop.
+ Condensing P. Circuit 1: op. loop...
+ Discharge T. Circuit 1 : op. loop...
- Discharge T. Circuit 1 : op. loop...
Entries
1/4
Access
Services
Commissioning
Status
Main Menu
1/4
Access
Services
Commissioning
Status
Main Menu
1/12
0.0%
0.0%
44°C
44°C
8.0°C
8.0°C
Cooling
HMI
Automatic
Delegate
Circuit 1
Hydraulic circuit
Capacity
Load
Current setp. heat
Heating setp.
Current setp. cool
Cooling setp.
Status from
Actual status
HMI status
HMI mode
Status
1/12
0.0%
0.0%
44°C
44°C
8.0°C
8.0°C
Cooling
HMI
Automatic
Delegate
Circuit 1
Hydraulic circuit
Capacity
Load
Current setp. heat
Heating setp.
Current setp. cool
Cooling setp.
Status from
Actual status
HMI status
HMI mode
Status
1/5
Load shedding
Reduced mode
On
Off
Delegate
HMI status
46 SYSAQUA R32
In the Monday submenu, 6 operating
intervals can be selected. For each time,
select the mode at which the unit must
operate:
² Off
² On
² Reduced mode
² Load shedding
To deactivate an operating interval, congure the corresponding time as follows: *:*.
The "Copy calendar" line copies the conguration made on Monday from Tuesday to Friday or from Tuesday
to Sunday.
The conguration of the weekdays can also be changed separately.
The rst line displayed shows the current mode at the level of time programming.
To ensure activation of the mode indicated in the calendar, the unit must operate in "Delegate"
mode.
Caution
14.5.3. ALARMS HISTORY
14.6. SCHEDULE
This history reports the 150 most recent activation or deactivation of alarms:
² Activation of an alarm will be indicated by a "+"
² Deactivation of an alarm will be indicated by a "-"
Alarm deactivated
Alarm 1 activated
Alarm 2 activated
For the activation and deactivation time of an alarm, select the alarm and
press the "enter" button .