MODBUS LITE V5.01 parameter specification
Table Of Contents
- 1 Frame protocol
- 2 Holding Register
- 2.1 Overview
- 2.2 Reset
- 2.3 Default set value
- 2.4 Password
- 2.5 Control default setting
- 2.6 Control customer setting
- 2.7 Operating hours counter
- 2.8 Operating minutes counter
- 2.9 Fan address
- 2.10 Source set value
- 2.11 Preferred running direction
- 2.12 Save set value
- 2.13 Internal parameter set
- 2.14 Control mode
- 2.15 Control parameters
- 2.16 Maximum modulation level
- 2.17 Minimum modulation level
- 2.18 Enable motor stop
- 2.19 Set value (EEPROM)
- 2.20 Starting modulation level
- 2.21 Maximum permissible modulation level
- 2.22 Minimum permissible modulation level
- 2.23 Maximum speed
- 2.24 Maximum permissible speed
- 2.25 Ramp-up curve / ramp-down curve
- 2.26 Limit speed
- 2.27 Potentiometer characteristic
- 2.28 Control limitation
- 2.29 Maximum power
- 2.30 Maximum coil current
- 2.31 Limiting speed for running monitor
- 2.32 Interface settings
- 2.33 Shedding function
- 2.34 Relay dropout delay
- 2.35 Fail safe function on/off
- 2.36 Fail safe function set value
- 2.37 Fail safe function time lag
- 2.38 Fail safe function running direction
- 2.39 Potentiometer characteristic limiting value for cable break
- 2.40 Sensor
- 2.41 Customer data
- 2.42 Error history
- 2.43 Reference value of DC-link voltage
- 2.44 Reference value of DC-link current
- 2.45 Production data
- 3 Input Register
- 3.1 Overview
- 3.2 Identification
- 3.3 Maximum number of bytes
- 3.4 Software name of bus controller
- 3.5 Software version of bus controller
- 3.6 Software name of commutation controller
- 3.7 Software version of commutation controller
- 3.8 Actual speed
- 3.9 Motor status
- 3.10 Warning
- 3.11 DC-link voltage
- 3.12 DC-link current
- 3.13 Module temperature
- 3.14 Motor temperature
- 3.15 Interior electronics temperature
- 3.16 Current direction of rotation
- 3.17 Current modulation level
- 3.18 Current set value
- 3.19 Sensor actual values
- 3.20 Current parameter set
- 3.21 Current power
MODBUS parameters "ebm-papst series 84 / 112 / 150 / 200"
_______________________________________________________________________________________
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 ·74673 Mulfingen, Germany ·Phone: +49 (0) 7938/81-0 ·Fax: +49 (0) 7938/81-110 ·www.ebmpapst.com ·info1@de.ebmpapst.com
DocNo.: 634505DocNo.: 446144DocNo.:358982DocNo.:322523DocNo.:309753DocNo.:303997DocNo.:276241DocNo.:256078DocNo.:196392 ·Template: 2 dated 6 October 2003 ·File: ext001157859.doc ·Last printed 10/03/2015 15:13:00
·Page 25 of 70
Form 1003
MODBUS
address
Designation
Write
ebm-papst
Write
customer
Write
end customer
Default
address
Cust. setting
address
D10F
Maximum modulation level (parameter set 2)
X
X
-
D28F
D20F
D110
Minimum modulation level (parameter set 1)
X
X
X
D290
D210
D111
Minimum modulation level (parameter set 2)
X
X
X
D291
D211
D112
Motor stop enable (parameter set 1)
X
X
X
D292
D212
D113
Motor stop enable (parameter set 2)
X
X
X
D293
D213
D114
Set value (parameter set 1)
X
X
X
D294
D214
D115
Set value (parameter set 2)
X
X
X
D295
D215
D116
Starting modulation level
X
-
-
D296
-
D117
Max. permissible modulation level
X
-
-
D297
-
D118
Min. permissible modulation level
X
-
-
D298
-
D119
Maximum speed
X
X
-
D299
D219
D11A
Max. permissible speed
X
-
-
D29A
-
D11B
Reserved
X
-
-
D29B
-
D11C
Reserved
X
-
-
D29C
-
D11D
Vacant
X
X
X
D29D
D21D
D11E
No function
X
-
-
D29E
-
D11F
Ramp-up time
X
X
X
D29F
D21F
D120
Ramp-down time
X
X
X
D2A0
D220
D121
Reserved
X
-
-
D2A1
-
D122
Reserved
X
-
-
D2A2
-
D123
Reserved
X
-
-
D2A3
-
D124
Reserved
X
-
-
D2A4
-
D125
Reserved
X
-
-
D2A5
-
D126
Reserved
X
-
-
D2A6
-
D127
Reserved
X
-
-
D2A7
-
D128
Limit speed
X
-
-
D2A8
-
D129
Reserved
X
-
-
D2A9
-
D12A
Potentiometer characteristic point 1 X-coordinate
(par. 1)
X
X
X
D2AA
D22A
D12B
Potentiometer characteristic point 1 Y-coordinate
(par. 1)
X
X
X
D2AB
D22B
D12C
Potentiometer characteristic point 2 X-coordinate
(par. 1)
X
X
X
D2AC
D22C
D12D
Potentiometer characteristic point 2 Y-coordinate
(par. 1)
X
X
X
D2AD
D22D
D12E
No function
X
X
X
D2AE
D22E
D12F
Control limitation
X
-
-
D2AF
-
D130
No function
X
X
-
D2B0
D230
D131
Reserved
X
-
-
D2B1
-
D132
No function
X
-
-
D2B2
-
D133
Reserved
X
-
-
D2B3
-
D134
Reserved
X
-
-
D2B4
-
D135
Max. permitted power
X
-
-
D2B5
-
D136
Maximum power at derating end
X
X
-
D2B6
D236
D137
Module temperature at start of derating
X
X
-
D2B7
D237
D138
Module temperature at end of derating
X
X
-
D2B8
D238
D139
Reserved
X
-
-
D2B9
-
D13A
Reserved
X
-
-
D2BA
-
D13B
Maximum coil current
X
-
-
D2BB
-
D13C
Potentiometer characteristic point 1 X-coordinate
(par. 2)
X
X
X
D2BC
D23C
D13D
Potentiometer characteristic point 1 Y-coordinate
X
X
X
D2BD
D23D