Installation, Operation and Maintenance instruction KV DUO Isolated box fan EC KVK DUO Isolated box fan AC/EC KVK Isolated box fan AC/EC KVK Silent Isolated box fan AC/EC KVK Slim Isolated box fan AC/EC
Table of content 1 Introduction .......................................................... 1 1.1 Product description ...................................... 1 1.2 Intended use .............................................. 1 1.3 Document description................................... 1 1.4 Product overview KV DUO EC and KVK DUO ......................................................... 1 1.5 Product overview KVK and KVK Silent ............. 1 1.6 Product overview KVK Slim ........................... 2 1.
1 Introduction 1.1 Product description environments with weather protection. The applicable ambient temperature of the installation location is from -25 °C to +70 °C during constant operation. The product is used in ventilation systems with circular ducts. The product is not applicable for transportation of air that contains explosive, flammable or aggressive media. The product is not applicable for locations where there is a risk of explosion.
1 2 3 8 4 7 5 6 1. 2. 3. 4. Service lid Fan impeller Mounting bracket Casing 1.6 5. 6. 7. 8. Name plate1 Connection box Duct connection Name plate1 Product overview KVK Slim Note: Parts such as the mounting bracket or the connection box are supplied loose in the casing on some models. 1 2 6 3 4 5 2 1. 2. 3. Name plate Service lid Mounting bracket 1. The name plate can be put in either one of these two positions. 4. 5. 6.
1.7 Name plate 1 2 3 4 5 6 1. Type designation: Product name, dimension and motor type. Refer to 1.7.1 Type designation page 3. 2. Input power, W 3. Frequency, Hz 13 4. Certifications 12 5. Scannable code 2 6. Find more information about the product on the Systemair documentation portal2 7. Country of production 8. Airflow direction arrow 9. Weight, kg 11 10 9 8 7 10. Serial number: part number/production number/production date 11. IP class, enclosure class 12. Current, A 13.
2 Safety • Read this manual and make sure that you understand the instructions before you do work on the product. 2.1 Safety definitions • Obey local conditions and laws. Warnings, cautions and notes are used to point out specially important parts of the manual. • Keep this manual at the location of the product. Warning • Do not install or operate the product if it is defective. If you do not obey these instructions, there is a risk of death or injury.
3 Transportation and storage 4 Installation 4.1 To do before the installation of the product Warning Make sure that the product does not become damaged or wet during transportation. A damaged or wet product can cause fire or electric shock. • Make sure that you have the necessary installation accessories: – Refer to 13 Accessory overview page 31 for an overview of the accessories. • Before you move the product to the installation location, examine the packaging for damages.
2 Open or remove the lid. 4.2.2 To attach the connection box Note: This procedure applies to products where the connection box is supplied loose inside the product. 1 Attach the connection box to the outlet side of the fan casing with the 4 supplied screws. Note: The arrow on the name plate shows the direction of the airflow. 4.2.1 1 To open the product Loosen the screws on the lid that is connected to the fan.
4.2.3 To install the KVK Silent fan and the KVK Slim fan 1 Attach the mounting bracket to the fan casing with the 4 supplied screws. 2 Attach the product to the floor, wall or the ceiling with 4 screws or 4 pendulum bars and screws. 4.2.4 1 Attach the product to the floor, the wall or the ceiling with screws. 4.2.5 1 To install the KVK DUO fan and the KVK fan To install the KV DUO 150 EC fan Fold out the 4 flaps from the fan casing.
2 Attach the product to the floor, the wall or the ceiling with 4 washers and 4 screws. 4.2.7 1 4.2.6 1 To install the KV DUO 400 – 630 EC fan Attach the product to the floor, the wall or the ceiling with screws through the outer mounting rails. To install the KV DUO 250 – 315 EC fan Attach the product to the floor, the wall or the ceiling with 4 screws through the 4 press nuts in the bottom of the fan casing. 4.2.
4 If you install the product near a duct bend, do these steps to prevent vibrations, unwanted noise and decreased air pressure: a. Measure the distance (A) between the product and the duct bend. b. Make sure that the distance (A) is a minimum of 2.5 x the diameter (B) of the duct system. For circular ducts, (B) is the nominal diameter. For rectangular ducts, (B) is the hydraulic diameter. A 5 Electrical connection 5.
5.6 To install motor protection for AC motors 6 Commissioning Caution • If the product has an built in motor protection, reset by disconnecting the product from power for 60 seconds. • If strong vibrations occur during commissioning, immediately increase or decrease the fan speed until the vibrations are decreased. Continuous strong vibrations can cause damage to components.
7 Operation Caution EC motors must be set to ON/OFF via the control input. To stop the product via mains supply decreases the life time of the motor. Systemair recommends to install external speed controller for easy access to control the input signal. 7.1 To start a product with an EC motor 1 Make sure that the 0–10 V signal is set to “0” with the speed controller. 2 Set the installed safety switch in the ON position and wait 5 seconds.
Maintenance task Usual operation conditions Each 6 months Each 3 months Each 6 months Visually examine the product and its components for damage, corrosion and dirt. X X Examine the fan impeller for damage and imbalance. X X Clean the product and the ventilation system. X Do a check of all fasteners and make sure that they are fully tightened. Make sure that the product and its components are correctly operated.
9 Troubleshooting Note: If you cannot find a solution to your problem in this section, speak to Systemair technical support. Problem Cause Solution The fan impeller is not correctly balanced. Speak to Systemair technical support. There is dirt on the fan impeller. Clean the fan impeller carefully. Refer to 8.2 To clean the product page 12. The fan impeller has damages or deformations because the transported air contains aggressive media. Speak to Systemair technical support.
Problem Cause Solution The fan impeller does not turn in the correct direction. Make sure that the electrical connection is correctly done. A phase loss occurred. If the motor is a 3-phase motor, make sure that no phase is missing. Note: This is not applicable for EC motors. The motor is overheated. Thermal contacts, PTC or resistors are released. • Do a check of the motor cooling impeller. • If it is possible, measure the resistance to do a check of the motor winding.
10 Disposal The product follows the WEEE directive. This symbol on the product or the packaging of the product shows that this product is not domestic waste. The product must be recycled at an approved disposal location for electrical and electronic equipment. 10.1 To disassemble and discard the parts of the product 1 Disconnect and disassemble the product in the opposite sequence of electrical connection and installation.
11 Warranty For warranty claims, send a written maintenance plan and the commissioning report to Systemair. The warranty is only applicable for these conditions: • The product is correctly installed and operated. • Motor protection is used. • The instructions in the data sheets are obeyed. • Maintenance instructions are obeyed. • A product that is not operated continuously is operated for a minimum of 1 hour each month. 12 Technical data 12.
E F D C A AC/EC G B H A B C D E ØF G H KVK Slim100 150 150 76 69 300 100 329 367 KVK Slim 125 150 150 72 84 300 125 329 367 KVK Slim 160 185 185 90 99 300 160 329 367 KVK Slim EC 100 150 150 76 69 300 100 329 367 KVK Slim EC 125 150 150 72 84 300 125 329 367 KVK Slim EC 160 185 185 90 99 300 160 329 367 C AC/EC D A E B F A B ØC D E F KVK Slim 200 542 620 200 270 415 513 KVK Slim 250 657 773 250 300 450 548 KVK Sl
AC/EC A B ØC D E F KVK Slim EC 200 542 620 200 270 415 513 KVK Slim EC 250 657 773 250 300 450 548 KVK Slim EC 315 746 866 315 414 590 694 KVK Slim EC 355 842 976 355 459 666 770 KVK Slim EC 400 842 1001 400 459 666 770 KVK Slim EC 500 1055 1213 500 605 768 873 12.2.2 Product dimensions KV DUO EC, KVK DUO Note: If the unit of measure is not specified, the dimensions are given in millimetres.
F G H A B C D E A B C D E F ØG H KVK DUO 125 165 255 510 425 350 275 125 333 KVK DUO 160 165 255 510 425 350 275 160 333 KVK DUO 200 190 300 600 475 400 325 200 386 KVK DUO 250 207 360 720 615 500 400 250 460 KVK DUO 315 L** 250 473 946 680 565 450 315 505 19
12.2.
K D E J F A G B H C AC/EC I c-c A B C ØD E F G c-c H I J K KVK Silent 200 561 604 681 198 351 249 498 551 595 155 810 KVK Silent 250 678 720 836 249 381 267 533 584 629 170 872 KVK Silent 315 828 906 1025 312 532 336 672 726 777 246 1165 KVK Silent 355 844 922 1041 352 578 424 848 902 952 269 1383 KVK Silent 400 844 922 1098 400 577 424 848 902 952 269 1383 KVK Silent 500 1055 1133 1292 500 676 425 850 904 954 341 14
E D F A B C H I G J K A B C ØD E F ØG H I J K KVK 125 151 114 367 125 230 266 6 40 464 415 40 KVK 160 M 134 132 367 160 230 266 6 40 464 415 40 KVK 160 L 134 132 367 160 230 266 6 40 464 415 40 KVK 200 191 193 395 200 340 345 6 40 440 395 40 KVK 250 198 228 460 250 380 385 6 40 490 400 40 12.
12.3.
1–phase 230 V KVK Silent 200 EC KVK Slim 200 EC KVK Silent 250 EC KVK Slim 250 EC 10V 0-10V GND TACHO RD YE BU N WH L BU BK YE/GN 1–phase 230 V KVK Silent 315 EC KVK Slim 315 EC KVK Silent 355 EC KVK Slim 355 EC KVK Silent 400 EC KVK Slim 400 EC KVK Silent 500 EC KVK Slim 500 EC 10V 0-10V GND RSA RSB COM NC RD YE BU WH BN N L WH WH BU BK YE/GN 3–phase 400 V 12.3.
A. Relay connection. There is always 230 V between line and neutral when the transformer knob is in one of the positions 1–5. B. Supply voltage C. Earth D. Fan REE — Thyristor RRE 1 and RRE 2 - Surface mounting or with flush mounting casing included. RRE 4 - Surface mounting. N Note: Starting currents must be considered when you select the speed controller type.
A. Relay connection. There is always 230 V between line and neutral when the transformer knob is in one of the positions 1–5. B. Mains supply C. Earth D. Fan E. Thermostat F. Motor protection. If the motor protection is not in use, Tk must be looped together. FRQ5S-E-6A Frequency converter with built in all pole sine filter and 5-step switch.
MTP 10 MTP 10 1 2 3/Us +10V 4/+ 0...10V 5/- GND MTP 20 MTP 20 1/Vdc+ +10V 4/Vout 0...10V 2/Vdc- GND 3/Vout- EC-Basic EC-Basic 1/IN Vac 230V AC 2/IN Vac +10V 4/Out 0...10V 5/GND GND MTV–1/10 MTV 1/010 1/IN Vac 230V AC 2/IN Vac +10V 4/Out+ 0...10V 5/Out- GND S-5EC/FRQ MTP 10 10V +10V GND 0...
EC-Vent EC-Vent optional IN/RPM IN/10V +10V PWM OUT/PWN GND 12.3.5 TACH 0...10V/PWM GND Wiring diagrams for ON/OFF controls for EC motors CO2RT-R(-D) CO2RT-R-D Supply +10V Neutral 0...10V Common GND 24V AC Relay NO Relay NC Din1 IR24–P IR24-P 24V +10V Neutral 0...10V Common GND 24V AC or DC Relay NO Relay NC 12.3.
EC Basic-U 1 2 3 4 V GND 0_10V 110-240 V~ 50/60Hz L N 0_10V GND EC Basic-U for universal 0-10 V control 5 6 7 OUT 8 IN EC-Vent Demand control for up to 5 external sensors, 2 fans, dampers, heaters and coolers. The EC vent system has 2 units. The control board (CB) and the room unit (RU). Connect the fan to the control board and remove the internal potentiometer. EC-Vent IN/RPM optional TACH IN/10V OUT/PWN +10V PWM 0...
A. Mains supply, 230 V 1~AC (10 A) B. Analogue sensor (for example, pressure sensor) C. Analogue sensor (for example, pressure sensor type PT1000) D. Digital sensor (for example, IR presence detector) E. Alarm output (maximum 24 V AC/DC, maximum 500 mA Cosφ >0.95) F. Output to EC fan G. Output to analogue actuator with 24 V DC supply H. Output to digital signal (DC, maximum 24 V, 1 maximum 50 mA) I. Output to analogue actuator (for example, heat regulator) J. Connection to Modbus K.
MM6-24/D output signal selector Compares signals from connected inputs and transfers the signal to the control output. 1 Input 1 0...10 V 2 Input 2 0...10 V 3 Input 3 0...10 V 4 Input 4 0...10 V 5 Input 5 0...10 V 6 Input 6 0...10 V 7 System neutral 8 24 V AC 9 Signal neutral 10 Signal neutral 11 Output minimum 0...10V 12 Output maximum 0...10V Mains supply PCA 1000D2 Pressure controller PCA 1000/6000D2 R i = 4 kΩ p PI V 1(+) 2( ) +US GND A GND + ∆p - + US 3 1 01 10...
5 4 3 1 2 7 5 6 10 11 8 9 12 1. 2. 3. 4. 5. 6. IGK: inlet louvre IGC: inlet louvre RSK: Back draft damper FGR/FFR: Filter cassette FK fast clamp Fan 7. 8. 9. 10. 11. 12. LDC: Silencer CWK: Water cooling battery VBC: Water heating battery CB and CBM: Electrical duct heaters SPI: Iris damper Balance S supply air diffuser Note: For more information about accessories, refer to www.systemair.com or speak to Systemair technical support.
14 EU Declaration of Conformity We, the manufacturer Manufacturer Systemair Sverige AB Address Industrivägen 3 739 30 Skinnskatteberg Sweden declare under our sole responsibility that the products Type/Model KV DUO, KVK DUO, KVK, KVK Slim, KVK Silent Identification Serial numbers dating from 2018 and onwards fulfils the relevant provisions of following directives and standards Machinery Directive 2006/42/EC EN ISO 12100:2010 Safety of machinery – General principles for design - Risk assessment and
15 UK Declaration of Conformity We, the manufacturer Manufacturer Systemair Sverige AB Address Industrivägen 3 SE-73930 Skinskatteberg Sweden declare under our sole responsibility that the products Type/Model KV DUO, KVK DUO, KVK, KVK Slim, KVK Silent Identification Serial numbers dating from 2018 and onwards fulfils the relevant provisions of following directives and standards Supply of Machinery (Safety) Regulations 2008 EN ISO 12100:2010 Safety of machinery – General principles for design - Ris
35
last page Systemair Sverige AB Industrivägen 3 SE-739 30 Skinnskatteberg +46 222 440 00 info@systemair.se www.systemair.se © Copyright Systemair AB All rights reserved EOE Systemair AB reserves the rights to alter their products without notice. This also applies to products already ordered, as long as it does not affect the previously agreed specifications.