FC101 Design Guide

Cable length [m (ft)] AC line voltage [V]
Rise time [μsec]
V
peak
[kV]
dU/dt [kV/μsec]
400 V 7.5 kW (10 hp)
5 (16) 400 0.168 0.81 3.857
25 (82) 400 0.239 1.026 3.434
50 (164) 400 0.328 1.05 2.560
400 V 11 kW (15 hp)
5 (16) 400 0.116 0.69 4.871
25 (82) 400 0.204 0.985 3.799
50 (164) 400 0.316 1.01 2.563
400 V 15 kW (20 hp)
5 (16) 400 0.139 0.864 4.955
50 (82) 400 0.338 1.008 2.365
400 V 18.5 kW (25 hp)
5 (16) 400 0.132 0.88 5.220
25 (82) 400 0.172 1.026 4.772
50 (164) 400 0.222 1.00 3.603
400 V 22 kW (30 hp)
5 (16) 400 0.132 0.88 5.220
25 (82) 400 0.172 1.026 4.772
50 (164) 400 0.222 1.00 3.603
400 V 30 kW (40 hp)
10 (33) 400 0.376 0.92 1.957
50 (164) 400 0.536 0.97 1.448
100 (328) 400 0.696 0.95 1.092
150 (492) 400 0.8 0.965 0.965
10 (33) 480 0.384 1.2 2.5
50 (164) 480 0.632 1.18 1.494
100 (328) 480 0.712 1.2 1.348
150 (492) 480 0.832 1.17 1.125
10 (33) 500 0.408 1.24 2.431
50 (164) 500 0.592 1.29 1.743
100 (328) 500 0.656 1.28 1.561
150 (492) 500 0.84 1.26 1.2
400 V 37 kW (50 hp)
10 (33) 400 0.276 0.928 2.69
50 (164) 400 0.432 1.02 1.889
10 (33) 480 0.272 1.17 3.441
50 (164) 480 0.384 1.21 2.521
10 (33) 500 0.288 1.2 3.333
50 (164) 500 0.384 1.27 2.646
400 V 45 kW (60 hp)
10 (33) 400 0.3 0.936 2.496
50 (164) 400 0.44 0.924 1.68
100 (328) 400 0.56 0.92 1.314
150 (492) 400 0.8 0.92 0.92
10 (33) 480 0.3 1.19 3.173
50 (164) 480 0.4 1.15 2.3
100 (328) 480 0.48 1.14 1.9
150 (492) 480 0.72 1.14 1.267
10 (33) 500 0.3 1.22 3.253
50 (164) 500 0.38 1.2 2.526
100 (328) 500 0.56 1.16 1.657
150 (492) 500 0.74 1.16 1.254
400 V 55 kW (74 hp) 10 (33)
400 0.46 1.12 1.948
480 0.468 1.3 2.222
400 V 75 kW (100 hp) 10 (33)
400 0.502 1.048 1.673
480 0.52 1.212 1.869
500 0.51 1.272 1.992
General Specications
VLT
®
HVAC Basic Drive FC 101
124 Danfoss A/S © 04/2018 All rights reserved. MG18C822