- VLT® HVAC Basic Drive FC 101
- English US
- Contents
- Introduction
- Safety
- Installation
- Mechanical Installation
- Electrical Installation
- Electrical Installation in General
- IT Mains
- Mains and Motor Connection
- Introduction
- Connecting to Mains and Motor
- Relays and Terminals on Enclosure Sizes H1–H5
- Relays and Terminals on Enclosure Size H6
- Relays and Terminals on Enclosure Size H7
- Relays and Terminals on Enclosure Size H8
- Connecting to Mains and Motor for Enclosure Size H9
- Relays and Terminals on Enclosure Size H10
- Enclosure Size I2
- Enclosure Size I3
- Enclosure Size I4
- IP54 Enclosure Sizes I2, I3, I4
- Enclosure size I6
- Enclosure size I7, I8
- Fuses and Circuit Breakers
- EMC-correct Electrical Installation
- Control Terminals
- Electrical Wiring
- Acoustic Noise or Vibration
- Programming
- Warnings and Alarms
- Specifications
- Index
- English US
Parameter Option Default Usage
Parameter 1-10
Motor Con-
struction
*[0] Asynchron
[1] PM, non-salient SPM
[3] PM, salient IPM
[0] Asynchron Setting the parameter value might change these parameters:
• Parameter 1-01 Motor Control Principle.
• Parameter 1-03 Torque Characteristics.
• Parameter 1-08 Motor Control Bandwidth.
• Parameter 1-14 Damping Gain.
• Parameter 1-15 Low Speed Filter Time Const.
• Parameter 1-16 High Speed Filter Time Const.
• Parameter 1-17 Voltage Filter Time Const.
• Parameter 1-20 Motor Power.
• Parameter 1-22 Motor Voltage.
• Parameter 1-23 Motor Frequency.
• Parameter 1-24 Motor Current.
• Parameter 1-25 Motor Nominal Speed.
• Parameter 1-26 Motor Cont. Rated Torque.
• Parameter 1-30 Stator Resistance (Rs).
• Parameter 1-33 Stator Leakage Reactance (X1).
• Parameter 1-35 Main Reactance (Xh).
• Parameter 1-37 d-axis Inductance (Ld).
• Parameter 1-38 q-axis Inductance (Lq).
• Parameter 1-39 Motor Poles.
• Parameter 1-40 Back EMF at 1000 RPM.
• Parameter 1-44 d-axis Inductance Sat. (LdSat).
• Parameter 1-45 q-axis Inductance Sat. (LqSat).
• Parameter 1-46 Position Detection Gain.
• Parameter 1-48 Current at Min Inductance for d-axis.
• Parameter 1-49 Current at Min Inductance for q-axis.
• Parameter 1-66 Min. Current at Low Speed.
• Parameter 1-70 PM Start Mode.
• Parameter 1-72 Start Function.
• Parameter 1-73 Flying Start.
• Parameter 1-80 Function at Stop.
• Parameter 1-82 Min Speed for Function at Stop [Hz].
• Parameter 1-90 Motor Thermal Protection.
• Parameter 2-00 DC Hold/Motor Preheat Current.
• Parameter 2-01 DC Brake Current.
• Parameter 2-02 DC Braking Time.
• Parameter 2-04 DC Brake Cut In Speed.
• Parameter 2-10 Brake Function.
• Parameter 4-14 Motor Speed High Limit [Hz].
• Parameter 4-19 Max Output Frequency.
• Parameter 4-58 Missing Motor Phase Function.
• Parameter 14-65 Speed Derate Dead Time Compensation.
Programming
Operating Guide | VLT® HVAC Basic Drive FC 101
AQ275641848264en-000101 / 132R0078
44 | Danfoss A/S © 2019.11