TWT DNV E 14035

Certificate No: E-14035
File No: 826.20
Job Id: 262.1-006733-2
Form code: TA 1411a
Revision: 2014-11
www.dnvgl.com
Page 2 of 2
Product description
Fan heater with the following types and sizes:
Type
Power
Voltage
Frequency
Ingress
Protection
TWT10321
300W
230V 1 ph
50 - 60Hz
IP 44
TWT10521
500W
230V 1 ph
50 - 60Hz
IP 44
TWT11021
1000W
230V 1 ph
50 - 60Hz
IP 44
TWT10331
300W
400V 3 ph
50 - 60Hz
IP 44
TWT10531
500W
400V 3 ph
50 - 60Hz
IP 44
TWT11031
1000W
400V 3 ph
50 - 60Hz
IP 44
Application/Limitation
For dry and wet accommodation spaces. Only for fixed installation. Shall normally be protected with a
top plate in accordance with our Rule Pt.4, Ch.8, Sec. 8, A 303. Installation is to be considered in each
case.
Type Approval documentation
Technical info:
ThermoWarmfor datasheet for Frico AB space heater of type TWT.
Nemco Test Report no. E10215.00 dated 2010-10-12, SEMKO type test report no. 813722-1 dated
2007-06. SEMKO test nos. SE-56183, SE-56184 & SE-56185 dated 2008-11-04. SEMKO report no.
715512/M dated 2008-10-09.
Tests carried out
Type tests according to IEC 60335-2-30, IEC 61892-3.
Marking of product
TWT Frico AB type designation
Periodical assessment
The scope of the periodical assessment is to verify that the conditions stipulated for the Type approval
are complied with and that no alterations are made to the product design or choice of materials.
The main elements of the periodical assessment are:
· Inspection on factory samples, selected at random from the production line (where practicable)
· Results from Production Sample Tests (PST) and Routines (RT) checked (if not available tests
according to PST and RT to be carried out)
· Review of type approval documentation
· Review of possible change in design, materials and performance
· Ensuring traceability between manufacturers product type marking and Type Approval Certificate.
Periodical assessment to be performed at least every second year.
END OF CERTIFICATE