2. INSPECTION AND STORAGE
At the time of receiving the equipment carefully cross check all the elements against the shipping documents
in order to ensure that all the crates and boxes have been received. Inspect all the units for any visible or
hidden damage.
In the event of shipping damage, write precise details of the damage on the shipper’s delivery note and
send immediately a registered letter to the shipper within 48 hours, clearly stating the damage caused.
Forward a copy of this letter to the manufacturer or his representative.
Never store or transport the unit upside down. It must be stored indoors, completely protected from
rain, snow etc. The unit must not be damaged by changes in the weather (high and low temperatures).
Excessively high temperatures (above 60 °C) can harm certain plastic materials and cause permanent
damage. Moreover, the performance of certain electrical or electronic components can be impaired.
The appliances are delivered fully assembled, factory tested and ready to operate.
Any modication to the units without the manufacturer’s prior approval, shall automatically render the
warranty null and void.
The following conditions must be respected in order to maintain the validity of the warranty:
² Commissioning shall be performed by specialised technicians from technical services approved by
the manufacturer.
² Maintenance shall be performed by technicians trained for this purpose.
² Only Original Equipment spare parts shall be used.
² All the operations listed in the present manual shall be performed within the required time limits.
THE WARRANTY SHALL BE NULL AND VOID IN THE EVENT
OF NON-COMPLIANCE WITH ANY OF THE ABOVE CONDITIONS.
3. WARRANTY
All the models in the SYSAQUA liquid coolers range are produced to state-of-the-art design and manufacturing
standards. In this way, they offer guarantees of high performance and reliability as well as the capability of
adapting to all types of air conditioning installations operating with both chilled water and glycol solutions
(and with hot water for the Heat pump units). The unit, designed for an outdoor mounted application, is not
suitable for any use other than those specied in the present manual.
Improper usage of the unit or a use for purposes other than those originally intended, without the prior
approval by the manufacturer or its agents, could result in the unit functioning outside its safe operating
limits and could present risks to both personnel and property.
4. PRESENTATION
SYSAQUA are packaged units, optimized for air conditioning applications.
After the units are assembled, the refrigerating and electrical circuits are tested at the factory in order to
guarantee correct operation.
The are lled with an operational refrigerant uid charge and are subjected to pressure tightness tests.
The Cooling only models can produce chilled water at temperatures varying between +18°C to +5°C or
chilled water/glycol solution at temperatures varying between +5°C to -10°C.
The Heat pump models can produce hot water at temperatures varying between +20°C and +50°C.