6. Insert the Check Valve into the outlet port
approximately 3/4" to 1" deep making sure the
rubber diaphragm facing outward (towards you),
see Diagram 1.
7. Reconnect the return hose to the outlet port and
tighten the union fitting.
8. Replace the drain cap.
9. Remove the rag from the skimmer or open the
valve on the suction line.
10. If the return line was plugged, unplug it at this time.
11. With the High Flow™ manual air relief valve in the
open position, start the filter pump, after a steady stream of water appears close the High Flow™
manual air relief valve.
12. Your system is now in operating order.
SECTION IV. INSTALLATION
To install this filter system, you will need the following simple tools - a screwdriver, pliers, and wrench.
1. Carefully remove the equipment from the carton and check for any evidence of damage due to
rough handling or shipping. If any of the equipment is damaged, immediately notify the
organization where the equipment was purchased.
2. Position a tee-nut on the boss underneath the skid base. Screw a bolt with washer into the tee-nut
from the top of the base. Continue screwing the bolt into the tee-nut until the tee-nut is flush with
the boss. Unscrew the bolt. Repeat procedure for the remaining bosses.
3. This filter should be mounted on a level concrete slab, preferably concrete poured in a form or on
a platform constructed of concrete block or brick.
4. Depending upon how your skimmer is positioned in
relationship to the return fitting, see Diagram 3, either
right or left of the skimmer, position the mounting base
accordingly; see Diagram 3. Position the filter tank on
the mounting base so the filter inlet port is oriented
toward the pump similar to Diagram 2. Secure the filter
to the mounting base using two bolt fasteners. Place
the pump on the mounting base; see Diagram 2.
Loosely attach the pump connector, see Detail A, to the
pump and filter. This will align the pump to the correct
set of mounting holes. Secure the pump to the base
using two bolt fasteners. Tighten the union fittings on
the plumbing connector by hand until tight. If water
leakage occurs at these connections, adjust
connections with a wrench making sure not to exceed 1/
4 of a turn.
Diagram 1.
inlet
Detail B
Diagram 2.
Detail C
Detail D
Detail A