Instructions
Intended use
The product can be used to control a window blind motor wirelessly
by radio. The transmitter can be any transmitter in the RSL wireless
switching system.
The blind actuator may only be used on mains voltage (230 V/AC,
50 Hz). For information on the power input required, see the section
“Technical Data”.
It is intended for indoor use only. Do not use it outdoors. Contact with
moisture, e.g. in bathrooms, must be avoided under all circumstances.
For safety and approval purposes, you must not rebuild and/or mo-
dify this product. If you use the product for purposes other than those
described above, the product may be damaged. In addition, improper
use can cause hazards such as short circuiting, re, electric shock
etc. Read the instructions carefully and keep them. Make this product
available to third parties only together with its operating instructions.
This product complies with the statutory national and European requi-
rements. All company names and product names are trademarks of
their respective owners. All rights reserved.
Safety instructions
Read the operating instructions carefully and espe-
cially observe the safety information. If you do not fol-
low the safety instructions and information on proper
handling in this manual, we assume no liability for any
resulting personal injury or damage to property. Such
cases will invalidate the warranty/guarantee.
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. This may
become dangerous playing material for children.
• Protect the product from extreme temperatures, direct sunlight,
strong jolts, high humidity, moisture, ammable gases, vapours and
solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of
operation and protect it from any accidental use. Safe operation can
no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions
or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even
from a low height can damage the product.
• Also observe the safety and operating instructions of any other de-
vices which are connected to the product.
• This product may only be installed by a qualied technician (e.g., an
electrician) who is familiar with the relevant regulations (e.g., VDE,
German electrical wiring regulations)!
Improper work carried out on the mains voltage endangers not only
your own life but also the life of others! There is a risk of a life-threat-
ening electric shock!
If you do not have the expertise required for the installation, do not
install it yourself but ask a qualied technician.
• Do not use this product in hospitals or medical institutions. Although
RSL System transmitters only emit relatively weak radio signals,
these may lead to the malfunctioning of life-support systems. The
same may also be the case in other areas.
• The product may only be operated on mains voltage (see sections
“Installation and Connection” and “Technical Data”). Never try to
operate the product at another voltage as this will cause its destruc-
tion.
• Perform installation only when all mains supply cables are dis-
connected from the mains voltage. Otherwise, there is a risk of a
life-threatening electric shock!
• The product may be installed and used only in dry indoor spaces; it
must not get damp or wet. Never touch the product with wet or damp
hands! There is a risk of a life-threatening electric shock!
• An all-pole disconnection from the mains voltage (such as a surge
protector) must be provided as part of the wiring set-up.
• Only use the product when it is securely installed and steady. Place
the product e.g. into an appropriate ush-mounted socket.
• If you have reason to assume that safe operation is no longer pos-
sible, disconnect the product immediately and secure it against in-
advertent operation. Do not touch the blind actuator or any device
connected to it.
Disconnect the blind actuator from the mains by switching off at the
appropriate circuit breaker or by pulling out the fuse. Furthermore,
turn off the earth leakage circuit breaker to disconnect all the poles
of the mains supply. After this, arrange for an expert to check the
product.
• In commercial institutions, the accident prevention regulations of
the Employer’s Liability Insurance Association for Electrical Sys-
tems and Operating Facilities are to be observed!
• Consult an expert when in doubt about operation, safety or connec-
tion of the device.
Latest operating instructions
Download the latest operating instructions via the
link www.conrad.com/downloads or scan the QR
code shown. Follow the instructions on the website.
Explanation of symbols
The lightning symbol inside a triangle is used when the-
re is a potential risk of personal injury, such as electric
shock.
An exclamation mark in a triangle indicates important ins-
tructions in this operating manual that absolutely have to
be observed.
The arrow symbol indicates specic tips and advice on
operation.
Delivery content
• RSL wireless blind actuator
• Operating instructions
Operating instructions
RSL wireless blind actuator
Item no. 1761739
• Maintenance, modications and repairs are to be performed exclu-
sively by an expert or at a qualied shop.
• If you have questions which remain unanswered by these operating
instructions, contact our technical support service or other technical
personnel.
Preparations for installation
Please refer to the section “Safety instructions”!
• Only one motor may be connected to the blind actuator.
• The blind actuator cannot detect the end position of the blind. Con-
nect only a motor that can switch itself off when the end positions at
the top and bottom of the blind are reached.
• The blind actuator may be mounted and operated only in a suitable
ush-mounted socket. It may only be operated when it is securely
mounted.
• The blind actuator must only be installed when the mains voltage
is switched off. Turn off the mains supply by switching off the ap-
propriate circuit breaker or by pulling out the fuse. Secure it against
unauthorised reconnection, e.g., with a danger sign.
Furthermore, turn off the earth leakage circuit breaker to disconnect
all the poles from the mains voltage.
• Check the mains connection for absence of voltage using a suitable
tester.
Installation and connection
Please refer to the section “Preparations for Installa-
tion”.
L
N
M
S1 S2 S-C NL
A B
C
A Control LED
B Control key
C Screw clamps
External button for “Raise blind”
External button for “Lower blind”
M Motor
L Phase of the mains cable
N Neutral line of the mains cable
The blind actuator can be used as a complementary component pro-
viding an additional wireless operation function for an existing blind
button. This means that the existing button for “Raise/lower blind”
remains intact; however, the motor that was previously operated by
it can now also be controlled with a wireless remote operation of the
RSL system.
For this purpose, the ush-mounted box needs sufcient space for
installing the blind actuator behind the blind button. Alternatively, the
blind actuator can be inserted in an additional ush-mounted box near
the blind button.
However, you can also completely replace the blind button with the
blind actuator, so that the blind motor can still be operated only by
radio. It is not necessary to connect a blind button to the connections
“S1,” “S2” and “S-C”!
• Remove the cover of your existing blind button and remove the but-
ton from the wall socket.
• Carry out the electrical connection via the screw clamps (C); see
the above diagram.
Connect the screw clamps “S1,” “S2” and “S-C” as shown in the
gure above with a blind button, if present.
The “S-C” screw clamp is the common connection of both buttons;
the connection “S1” serves for the button function “ ” (downwards),
the connection “S2” for the button function “ ” (upwards).
If the electrical wires for the motor’s direction control
are accidentally reversed at this point, then the rotation
direction can later be changed during the programming
process.