Hardware Manual
Hardware Manual / EQU RTK
Swiss Timing, Ltd. Version 1.1 Page 6 of 23
RTK_EQU_Tracking_System_Hardware-Manual.docx
4.3 Electrical Specification
Make sure that your intended power supply for the RTK Base Station does not
exceed the voltage limits of 12 – 24 VDC in order to prevent malfunction or damage
to the device.
Pinouts and voltage ratings for the POWER/SERIAL and DATA/POWER OUT connectors are set out in the table
below.
CONNECTOR NAME
CONNECTOR
REFERENCE
PIN ID
SIGNAL DESCRIPTION
DATA/POWER OUT
M12 8pFT-X
1
2
3
4
5
6
7
8
Ethernet: TX+
Ethernet: TX-
Ethernet: RX+
Ethernet: RX-
Power supply: 12 – 24 VDC
Power supply: 12 – 24 VDC
Power supply: GND
Power supply: GND
POWER/SERIAL
M12 8pMT-A
1
2
3
4
5
6
7
8
RS422: RX+
RS422: RX-
Power supply: GND
RS422: TX+
RS422: TX-
Power supply: GND
Power supply: 12 – 24 VDC
Power supply: 12 – 24 VDC
4.4 LED Status
The device is equipped with two status LEDs. The blue LED illuminates when the device is properly supplied with
power. The green LED flashes during GNSS signal acquisition and fully illuminates as soon as it has a proper GNSS
fix. The device is fully operational when both status LEDs are light up.
Figure 5: Status LEDs on the RTK Base Station
POWER: blue LED
GNSS: green LED