Installation Instructions

Panel Installation
Fumes Hazard
The fumes from the silicone and solvents
used by the installer can be harmful if used
in an unventilated room. Always work in a well-ventilated
area. To keep the area well-ventilated, open windows and
use exhaust fans. If adequate ventilation is not achievable
or practical, use respiratory protective equipment.
1. Clean the backs of each panel with denatured alcohol or
another non oil-based cleaning solvent.
Do not use oil-based cleaners, such as mineral spirits, to clean
the panels. The oil in the cleaner will prevent the panel from
adhering properly to the wall.
2. Apply the silicone in 1-1/4” diameter dots every 8 to 10
inches apart over the surface of the panel. Follow the
silicone manufacturer’s instructions and all ventilation and
installation precautions.
Note: When using an industrial grade hot melt glue gun to
secure the panels to the wall in place of bracing,
apply the silicone as stated in Step 2. Then apply
the hot melt glue to the panel, as needed, and
quickly press the panel rmly into place. Also
refer to the WARNING for hot melt glue applications.
This process is not recommended for the do-it-yourself
homeowner.
Using hot melt glue in place of bracing requires application
by a qualied installer. This temporary bonding method
must hold the panel to the wall during the 24 hour curing
time of the silicone sealant. The hot melt glue by itself
is not sufcient to bond the panel to the wall. Therefore,
improper or inadequate application of the hot melt glue
may result in insufcient bonding of the panel to the
wall. Due to the weight of the panel, failure to follow this
recommendation may allow it to detach itself from the
wall, causing possible injury to someone in or around the
bathtub.
Improper installation methods may also result in water
damage or other damage to oors, walls, or other portions
of your building or home.
Do not use a home applicator, craft-type hot melt glue gun.
Using this type of glue gun will NOT hold the panels in place
long enough for the silicone to bond properly to the wall.
3. nstall back panel (1) rst. Then, install left-hand panel (2).
Finally, install right-hand panel (3).
4. For the SB-60-5 model, follow these steps
a. Select any one of the four at panels for
positioning on the back wall. Apply sealant to the
back of the panel, keeping the sealant at least one
inch from the panel edges.
1
2 3
IMPORTANT NOTICE
WARNING
WARNING
IMPORTANT NOTICE
Swan 12 800-325-7008
Installation Procedure