Power supply connection
NOTE
Use a power supply adaptor of DC 12 V (± 10%) with a minimum of 1,000 mA or DC 24V (± 10%) with a minimum of 500 mA which
has obtained the approval of IEC/EN 60950-1. If you wish to connect and use another device to the power supply adaptor, you
should use an adaptor with a current capacity which is the same or larger than the total power consumption required for the
terminal and another device.
Use a separate power supply for Secure I/O 2, the electric lock, and the product respectively. If connecting and using the power
supply to these devices together, the devices may malfunction.
Network connection
TCP/IP
LAN connection (connecting to a hub)
You can connect the product to a hub using a general type CAT-5e cable.
PC
Hub
XPass 2
XPass 2
21 - PWR +VDC Red
22 - PWR GND Black (White stripe)
DC power