BioEntry device is connected to the controller by ABA Track II output, not by
Wiegand interface, you should check Use ABA Track II. In that case, the output
signal will be in ABA Track II format. You can also specify the number of
characters for ABA Track II output.
26 bit standard
The 26 bit standard format is most widely used and consists of 8 bit FC code and
16 bit ID. You cannot change the bit definition and the parity bits in 26 bit standard
format.
Pass Through format
Pass Through format is used when only the format of ID field is known. When the
Wiegand input string is detected, BioEntry device extracts ID bits and starts
verification with the ID. If the verification succeeds, the device outputs the Wiegand
input string as unchanged. Parity check and advanced options are ignored in this
format. By definition, Pass Through format is only useful when the operation mode
is 1:1. If the mode is 1:N, the bits other than ID field are set to 0.
For example, assume that 32 bit Pass Through format is composed as follows:
XIIIIIII IIIIIIIX XXXIIIII IIIIIIIX (left most bit is 0th bit, BIT0)
I: Id field, X: Unknown field
You can configure this format in the following sequences.