Owner Manual
26
|
Gas Requirements
The tip of the spark plug or thermocouple must
fully overlap at
least the rst gas emission hole of the burner.
After performing all these visual checks, reinstall
the bottom panel of the oven compartment and
proceed to setting the minimum for each burner.
STEP 6: MINIMUM FLAME ADJUSTMENT
WARNING! These adjustments should be made
only for use of the appliance with natural gas. For
use with liquid propane gas, the By-pass screw must
be fully turned in a clockwise direction.
SURFACE BURNERS
1. Light one burner at a time and set the knob to the
MINIMUM position (small ame).
2. Remove the knob.
3. The range is equipped with a safety valve. Using a
small size slotted screwdriver, locate the By-pass
screw valve on the valve body and turn it to the
right or left until the burner ame is adjusted to
desired minimum.
4. Make sure that the ame does not go out when
switching quickly from the MAXIMUM to the
MINIMUM position.
For surface worktop burners
For simmer burners, on the tap in the right
OVEN BURNER
1. Set the oven temperature control knob to the
MAXIMUM setting.
2. Close the oven door and operate the oven for at
least 10 minutes.
3. Set the knob to the MINIMUM setting
4. Remove the knob.
5. With a slotted screwdriver turn the choking
screw (bypass screw at the left side of the
thermostat bar) and, while observing the ame
at the same time through the bottom oven
porthole, evaluate the consistency of the ame
so it remains on when switching quickly from
MINIMUM to MAXIMUM setting.