User's Manual

Chapter 3 Installing and Powering On the Sun Blade X6270 Server Module 39
Note The OK/Power LED will be set to standby blink only when there is enough
chassis power for the server module to power on. If there is not enough chassis
power, the OK/Power LED will remain off until there is enough power for the
server module to power on. To troubleshoot this issue, see “Troubleshoot Server
Power States” on page 40.
At this time, standby power is supplied to the server module SP enabling you to
connect to ILOM and configure an IP address. Note that main power to the server
module host must be applied prior to installing an operating system.
Apply Main Power to Server SP and Host
1. Verify that the OK/Power LED on the front panel of the server module is in a
standby blink state.
In standby power state, the OK/Power LED on the front panel of the server
module illuminates a slow blink (0.1 second on, 2.9 seconds off).
Note The server power state will not be set to standby if the CMM in the chassis
is not present or accessible to the server SP. The OK/Power LED on the server will
remain off. In this situation, you should proceed by powering on the server as
instructed below.
2. Use a non-conductive pointed object or stylus to press and release the recessed
Power button on the server module front panel.
The OK/Power LED on the server module front panel illuminates a steady-on
green light. The steady-on LED state indicates that the server module SP and host
are both powered-on.