USER MANUAL INDUSTRIAL AIR COMPRESSOR SHOPTEK™ ST400, ST500, ST700, ST1100, ST1500 4, 5, 7, 11 &15 KW: 5, 7.
AIR CARE SEMINAR TRAINING Sullair Air Care Seminars are courses that provide hands-on instruction for the proper operation, maintenance, and servicing of Sullair products. Individual seminars on Industrial compressors and compressor electrical systems are offered at regular intervals throughout the year at Sullair’s corporate headquarters training facility located at Michigan City, Indiana.
TABLE OF CONTENTS SECTION 1—SAFETY 3 1.1 GENERAL 3 1.2 PERSONAL PROTECTIVE EQUIPMENT 3 1.3 PRESSURE RELEASE 4 1.4 FIRE AND EXPLOSION 4 1.5 MOVING PARTS 5 1.6 HOT SURFACES, SHARP EDGES AND SHARP CORNERS 5 1.7 TOXIC AND IRRITATING SUBSTANCES 6 1.8 ELECTRICAL SHOCK 6 1.9 LIFTING 7 1.10 ENTRAPMENT SECTION 2—DESCRIPTION 9 2.1 INTRODUCTION 9 2.2 COMPRESSOR COMPONENT DESCRIPTION 14 2.3 COMPRESSOR COOLING AND LUBRICATION SYSTEM — FUNCTIONAL DESCRIPTION 14 2.
TABLE OF CONTENTS SECTION 5—OPERATION 55 5.1 ROUTINE OPERATION SECTION 6—MAINTENANCE 57 6.1 GENERAL 57 6.2 MAINTENANCE AFTER INITIAL 50 HOURS OF OPERATION 58 6.3 MAINTENANCE EVERY 2000 HOURS 58 6.4 FLUID MAINTENANCE 58 6.5 FILTER MAINTENANCE 59 6.6 AIR FILTER MAINTENANCE 60 6.7 SEPARATOR MAINTENANCE 61 6.8 BELT MAINTENANCE 65 6.9 REPLACEMENT AND ALIGNMENT OF BELT PULLEYS 66 6.10 HOSE MAINTENANCE 66 6.11 TANK MOUNT PACKAGE MAINTENANCE 66 6.
Section 1 SAFETY NOTE the precautionary statements contained herein are applicable to most compressors and the concepts behind these statements are generally applicable to all compressors. 1.2 OPERATOR IS REQUIRED TO READ ENTIRE INSTRUCTION MANUAL. 1.1 GENERAL Sullair Corporation and its subsidiaries design and manufacture all of their products so they can be operated safely. However, the responsibility for safe operation rests with those who use and maintain these products.
SECTION 1 accumulate on, under or around acoustical material, or on any external surfaces of the air compressor. Wipe down using an aqueous industrial cleaner or steam clean as required. If necessary, remove acoustical material, clean all surfaces and then replace acoustical material. Any acoustical material with a protective covering that has been torn or punctured should be replaced immediately to prevent accumulation of liquids or fluid film within the material.
SECTION 1 C. Wear snug-fitting clothing and confine long hair when working around this compressor, especially when exposed to hot or moving parts. DANGER D. Keep access doors, if any, closed except when making repairs or adjustments. E. Make sure all personnel are out of and/or clear of the compressor prior to attempting to start or operate it. F.
SECTION 1 swallowed, induce vomiting by administering a tablespoon of salt, in each glass of clean, warm water until vomit is clear, then administer two teaspoons of baking soda in a glass of clean water. Have patient lay down and cover eyes to exclude light. Call a physician immediately. 1.
SECTION 1 I. Keep lift operator in constant attendance whenever compressor is suspended. J. Set compressor down only on a level surface capable of safely supporting at least its weight and its loading unit. K. When moving the compressor by forklift truck, utilize fork pockets if provided. Otherwise, utilize pallet if provided. If neither fork pockets or pallet are provided, then make sure compressor is secure and well balanced on forks before attempting to raise or transport it any significant distance.
NOTES 8
SHOPTEK™ USER MANUAL Section 2 DESCRIPTION 2.1 INTRODUCTION The design of the Sullair ShopTek line of compressor units is a single stage, positive displacement, flooded rotary screw. A complete package includes the: • Compressor unit External piping, connectors, and the enclosure should be inspected and maintained in accordance with the procedures and recommendations in this manual. 2.
SHOPTEK™ USER MANUAL SECTION 2 Figure 2-1: Main Components, ST400, ST500, ST 700, 5 -10 HP 1. Fluid Filter 7. E-Stop Button 2. Fluid Cooler 8. Controller 3. Air Inlet Filter 9. Main Motor 4. Separator Tube 10. Compressor Unit 5. Fluid Fill Sight Glass 11. Cooler Fan Motor 6.
SECTION 2 SHOPTEK™ USER MANUAL Figure 2-2: Main Components, ST1100, ST1500, 15-20 HP 1. Fluid Filter 7. E-Stop Button 2. Aftercooler/Fluid Cooler 8. Controller 3. Air Inlet Filter 9. Main Motor 4. Separator Tube 10. Compressor Unit 5. Fluid Fill Sight Glass 11. Cooler Fan Motor 6.
SHOPTEK™ USER MANUAL SECTION 2 COOLING/LUBRICATION SYSTEM 6 7 8 DISCHARGE SYSTEM Figure 2-3: Cooling/Lubrication and Discharge System ST400, ST500 and ST700 5-10 HP 12 1. Separator Tube 5. Separator Element 2. Cooler 6. Air 3. Fluid Filter 7. Air/Fluid Mix 4. Compressor Unit 8.
SECTION 2 SHOPTEK™ USER MANUAL COOLING/LUBRICATION SYSTEM 6 DISCHARGE SYSTEM 7 5 8 Figure 2-4: Cooling/Lubrication and Discharge System ST1100 and ST1500 15 & 20 HP 1. Separator Tube 5. Separator Element 2. Cooler 6. Air 3. Fluid Filter 7. Air/Fluid Mix 4. Compressor Unit 8.
SHOPTEK™ USER MANUAL 2.3 SECTION 2 COMPRESSOR COOLING AND LUBRICATION SYSTEM — FUNCTIONAL DESCRIPTION Refer to Figure 2-3 and Figure 2-4. The cooling and lubrication system consists of a fan, fan motor, aftercooler (ST1100/ST1500 15-20HP only) /fluid cooler, full flow fluid filter, thermal valve, interconnecting hoses and separator tube.
SECTION 2 SHOPTEK™ USER MANUAL Other pressure settings can be selected depending on compressor application or rating. START MODE - 0 TO 50 PSIG (0 TO 3.5 BAR) There is no load on the compressor at startup, the solenoid valve is open and the inlet valve is closed. When the compressor (START) pad is pressed, the separator tube pressure rises from 0 to 50 psig (0 - 3.4 bar). When it reaches its full operating speed (maximum rpm), the compressor switches to the Full Load Mode.
SHOPTEK™ USER MANUAL SECTION 2 Figure 2-6: Control System, ST1100, ST1500, 15-20 HP 1. Air Outlet 5. Separator Tube 2. Unload Solenoid Valve 6. Pressure Transducer 3. Air Inlet 7. Controller 4. Minimum Pressure/Check Valve service line pressure will rise. The Controller deenergizes the solenoid valve when the pressure exceeds 127 psig (8.8 bar) allowing the separator tube air pressure to be supplied directly which closes the inlet valve.
SECTION 2 2.6 SHOPTEK™ USER MANUAL AIR INLET SYSTEM, FUNCTIONAL DESCRIPTION Refer to Figure 2-7 and Figure 2-8. The compressor inlet system consists of a dry-type air filter and an air inlet valve. Figure 2-8: Air Inet System-ST1100, ST1500, 15-20 HP Figure 2-7: Air Inet System-ST400, ST500, ST700, 5-10 HP 1. Air Inlet Filter 4. Clamp 2. Clamp 5. Compressor Unit 3. Inlet Tube 1. Air Inlet Filter 3. Inlet Adaptor 2. Clamp 4.
SHOPTEK™ USER MANUAL SECTION 2 ® 1 X 2 3 S 4 11 10 9 8 7 5 6 Figure 2-9: Controller Panel 1. Run Mode Indicator Light (Green) 6. Start Button 2. Power On Indicator Light (Red) 7. Return/Reset Button 3. Fault Warning Indicator Light (Red) 8. Cursor/Confirm Button 4. Display Panel 9. Up Button 5. Stop Button 10. Down Button 11. Set/Load/Unload Button 2.7 CONTROLLER/KEYPAD Refer to Figure 2-9. The Controller keypad has two main pads for compressor control.
SECTION 2 SHOPTEK™ USER MANUAL The lower line will display the cause of the fault. Refer to service instructions to correct the cause. Press and hold the Return/Reset pad to reset LOAD PRESS: 0110PSI the controller. Refer to Figure 2-11. Press the Down arrow to display additional information about the compressor. The upper line will indicate the name of the temperature, pressure, or other measurement. The lower line indicates the present reading. TOTAL RUN TIME: 337H 20M Refer to Figure 2-12.
NOTES 20 02250180-090 R00
SHOPTEK™ USER MANUAL Section 3 SPECIFICATIONS 3.1 TABLE OF SPECIFICATIONS DIMENSIONS Width Height Length Model (I) ST400 Series ST410 ST410 ST500 Series ST510 ST510 ST700 Series ST709 ST712 ST708 ST713 ST1100 Series ST1109 ST1112 ST1108 ST1113 ST1500 Series ST1509 ST1512 ST1508 ST1513 Weight in mm in mm in mm lbs kg 60 50 32.5 32.5 826 826 21.5 21.5 546 546 37 37 940 940 524 524 238 238 7.5 7.5 60 50 32.5 32.5 826 826 21.5 21.
SHOPTEK™ USER MANUAL 3.2 SECTION 3 COMPRESSOR SPECIFICATIONS COMPRESSOR: STANDARD MODELS: Type: Fluid Flooded Rotary Screw Standard Operating Pressure: 115 psig (8 bar) / 125 psig (8.6 bar)/145 psig (10.0 bar)/ 150 psig (10.3 bar) 175 psig (12.0 bar)/188 psig (13.0 bar) Bearing Type: Anti-friction Ambient Temperature (Max.) 104ºF (40ºC) 3.3 LUBRICATION GUIDE Refer to Figure 3-1 for the fluid fill port location.
SECTION 3 SHOPTEK™ USER MANUAL NOTE When performing a fluid change or topping off: With machine off, fill to the bottom of the fill port. Sight glass will be completely full. Mixing, changing or adding other lubricants within the compressor unit may void the air-end warranty. Figure 3-1: Fluid Fill Location 3.5 1. Separator Tube 3. Fluid Fill Port 2. Sight Glass 4.
SHOPTEK™ USER MANUAL 24 Figure 3-2: Identification - ST400, ST500, ST700, 5-10HP 02250180-090 R00 SECTION 3 02250179-432 R00
SEE TABLE NOTES: 1. ALLOW 4.00 FEET [1.25 METERS] MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR. SECTION 3 Identification - ST400, ST500, ST700, 5-10HP 2. A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO MAINTAIN THE COMPRESSSOR FRAME LEVEL IS REQUIRED. 3. ALL DIMENSIONS ARE +/- .50” [12.7MM] 4. RECOMMENDED INCOMING CUSTOMER POWER SUPPLY IS SHOWN ON DRAWING. 5. DOORS ARE REMOVABLE USING LIFT-OFF PINS. 6.
SHOPTEK™ USER MANUAL 26 Figure 3-3: Identification - ST1100, ST1500, 15-20HP 02250180-090 R00 SECTION 3 02250179-435 R01
SEE TABLE NOTES: 1. ALLOW 4.00 FEET [1.25 METERS] MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR. 2. A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO MAINTAIN THE COMPRESSSOR FRAME LEVEL IS REQUIRED. SECTION 3 Identification - ST1100, ST1500, 15-20HP 3. ALL DIMENSIONS ARE +/- .50” [12.7MM] 4. RECOMMENDED INCOMING CUSTOMER POWER SUPPLY IS SHOWN ON DRAWING. 5. DOORS ARE REMOVABLE USING LIFT-OFF PINS. 6.
SHOPTEK™ USER MANUAL 28 Figure 3-4: Piping and Instrumentation - ST400, ST500, ST700, 5-10HP 02250180-090 R00 SECTION 3 02250179-804 R01
PART NO. Q T Y 1 88290014-486 1 FILTER,AIR 2 - 1 VALVE,INLET INTEGRAL 3 VARIOUS 1 MOTOR,ELECTRIC 4 02250171-669 1 UNIT,COMPRESSOR 5 88290014-534 1 PROBE,TEMP 6 88290015-814 1 SEPARATOR TUBE 7 88290015-049 1 ELEMENT,OIL SEPARATOR 8 88290014-222 1 OIL SIGHT GLASS KEY NO.
SHOPTEK™ USER MANUAL 30 Figure 3-5: Piping and Instrumentation - ST1100 and ST1500, 15-20HP 02250180-090 R00 SECTION 3 02250179-805 R02
1 88290014-485 1 FILTER,AIR 2 - 1 VALVE,INLET INTEGRAL 3 VARIOUS 1 MOTOR,ELECTRIC 4 88290015-893 1 UNIT,COMPRESSOR 5 88290014-534 1 PROBE,TEMP 6 88290014-226 1 SEPARATOR TUBE 7 88290015-567 1 ELEMENT,OIL SEPARATOR 8 88290014-222 1 OIL SIGHT GLASS 9 02250046-338 1 VALVE,MINIMUM PRESSURE 10 88290014-225 1 COMBINATION AIR/OIL COOLER 11 88290014-514 1 SENSOR,PRESSURE 12 VARIOUS 1 VALVE,RELIEF 13 88290015-890 1 FILTER,RETURN OIL 14 VARIOUS 1 VALVE,THERMAL 1
SHOPTEK™ USER MANUAL 32 Figure 3-6: Wiring Diagram - ST400-ST1500 208V-460V Full Voltage 02250180-090 R00 SECTION 3 88290015-618 R0
SECTION 3 Figure 3-7: Wiring Diagram - ST400-ST1500 575V Full Voltage 02250180-090 R00 33 SHOPTEK™ USER MANUAL 88290017-537 R03
SHOPTEK™ USER MANUAL 34 Figure 3-8: Wiring Diagram - ST400, ST500, ST700 400V/50Hz CE Full Voltage 02250180-090 R00 SECTION 3 88290014-361 R07
SECTION 3 Figure 3-9: Wiring Diagram - ST1100-ST1500 400V/50Hz CE Wye-Delta 02250180-090 R00 SHOPTEK™ USER MANUAL 35 88290014-360 R09
SHOPTEK™ USER MANUAL 3.6 SECTION 3 TANK MOUNT AND DRYER OPTIONS DIMENSIONS Width Height Length Model (I)(II) WS400 Series ST400R ST400RD Weight HP in mm in mm in mm lbs kg 5 5 64 69 1616 1748 23 23 591 591 63 63 1605 1605 854 935 388 424 7.5 7.5 64 69 1616 1748 23 23 591 591 63 63 1605 1605 876 954.5 398 434 10 10 64 69 1616 1748 23 23 591 591 63 63 1605 1605 897 981 408 446 15 15 66 71 1676 1797 25.5 25.5 645.5 645.5 71.5 71.5 1813.5 1813.
NOTES 02250180-090 R00 37
SECTION 3 Figure 3-10: Identification - ST400, ST500, ST700, 5-10HP Tank Mount 02250180-090 R00 38 SHOPTEK™ USER MANUAL 02250179-433 R00
SEE TABLE NOTES: 1. ALLOW 4.00 FEET [1.25 METERS] MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR. 2. A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO MAINTAIN THE COMPRESSSOR FRAME LEVEL IS REQUIRED. SECTION 3 Identification - ST400, ST500, ST700, 5-10HP Tank Mount 3. ALL DIMENSIONS ARE +/- .50” [12.7MM] 4. RECOMMENDED INCOMING CUSTOMER POWER SUPPLY IS SHOWN ON DRAWING. 5. DOORS ARE REMOVABLE USING LIFT-OFF PINS. 6.
SECTION 3 Figure 3-11: Identification - ST400, ST500, ST700, 5-10HP Tank Mount with Dryer 02250180-090 R00 SHOPTEK™ USER MANUAL 40 02250179-434 R00
SEE TABLE NOTES: 1. ALLOW 4.00 FEET [1.25 METERS] MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR. 2. A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO MAINTAIN THE COMPRESSSOR FRAME LEVEL IS REQUIRED. SECTION 3 Identification - ST400, ST500, ST700, 5-10HP Tank Mount with Dryer 3. ALL DIMENSIONS ARE +/- .50” [12.7MM] 4. RECOMMENDED INCOMING CUSTOMER POWER SUPPLY IS SHOWN ON DRAWING. 5. DOORS ARE REMOVABLE USING LIFT-OFF PINS. 6.
SHOPTEK™ USER MANUAL 42 Figure 3-12: Identification - ST1100, ST1500, 15-20HP Tank Mount 02250180-090 R00 SECTION 3 02250179-436 R01
SEE TABLE NOTES: 1. ALLOW 4.00 FEET [1.25 METERS] MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR. 2. A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO MAINTAIN THE COMPRESSSOR FRAME LEVEL IS REQUIRED. SECTION 3 Identification - ST1100, ST1500, 15-20HP Tank Mount 3. ALL DIMENSIONS ARE +/- .50” [12.7MM] 4. RECOMMENDED INCOMING CUSTOMER POWER SUPPLY IS SHOWN ON DRAWING. 5. DOORS ARE REMOVABLE USING LIFT-OFF PINS. 6.
SHOPTEK™ USER MANUAL 44 Figure 3-13: Identification - ST1100, ST1500, 15-20HP Tank Mount with Dryer 02250180-090 R00 SECTION 3 02250179-437 R01
SEE TABLE NOTES: 1. ALLOW 4.00 FEET [1.25 METERS] MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR. SECTION 3 Identification - ST1100, ST1500, 15-20HP Tank Mount with Dryer 2. A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO MAINTAIN THE COMPRESSSOR FRAME LEVEL IS REQUIRED. 3. ALL DIMENSIONS ARE +/- .50” [12.7MM] 4. RECOMMENDED INCOMING CUSTOMER POWER SUPPLY IS SHOWN ON DRAWING. 5. DOORS ARE REMOVABLE USING LIFT-OFF PINS. 6.
SHOPTEK™ USER MANUAL 46 Figure 3-14: Wiring Diagram - SRS 25-100 115-230V/1/60 02250180-090 R00 SECTION 3
SECTION 3 Figure 3-15: Wiring Diagram - SRS 9-18 220-240V/1/50 02250180-090 R00 SHOPTEK™ USER MANUAL 47
SHOPTEK™ USER MANUAL 48 Figure 3-16: Wiring Diagram - SRS 24-30 220-240V/1/50 02250180-090 R00 SECTION 3
SHOPTEK™ USER MANUAL Section 4 INSTALLATION 4.1 COMPRESSOR MOUNTING SUPPORT AND LOCATION The compressor must have a stable firm foundation, or mounting structure that is rigid enough to keep the compressor frame level, and maintain the alignment of the compressor and motor. Tie-down bolts of sufficient size must be used to ensure that the compressor frame is firmly anchored to its foundation.
SHOPTEK™ USER MANUAL SECTION 4 Table 4-1: Ventilation Requirements Model Ventilation Air Required cfm m3/hr ST400 612 1040 ST500 612 1040 ST700 612 1040 ST1100 1471 2500 ST1500 1471 2500 OUTDOOR INSTALLATION (SHELTERED) ShopTek packages are equipped with TEFC motors and have water tight controls that are NEMA 4 rated and are suitable for sheltered outdoor installation. The compressor should be mounted on a concrete pad.
SECTION 4 SHOPTEK™ USER MANUAL Figure 4-2: ST1100, ST1500 Shipping Studs 1. Belt Guard 3. Shipping Studs (2) 2. Nut (2) 4.3 SERVICE AIR PIPING PIPE SIZING Before installing the compressor, review the service air system’s layout including: pipe sizes, auxiliary separator tube, drip legs, line filter(s), and isolation valves (See Figure 4-3). Pipes should be sized as a minimum to match the dimensions of the compressor’s discharge connection.
SHOPTEK™ USER MANUAL SECTION 4 ISOLATION VALVES FLUID CONTAINMENT Install isolation valves where isolation of the compressor from the service lines is required. These valves should have drip legs that drain at an angle downward from the base. A vent to the piping should be installed downstream of the compressor outlet connection. Compressors have a fluid containment pan to collect fluid leaks or spills. The pan has a drain located on the front side of the machine.
SECTION 4 SHOPTEK™ USER MANUAL during compressor operation. Check the fluid level by looking at the sight glass on the separator tube when the compressor is in the SHUT DOWN MODE (fluid level may not be visible when operating). In this condition the sight glass should be completely full. Add fluid if the level is visible or if no fluid is visible at all. 4.6 ELECTRICAL PREPARATION Interior electrical wiring is installed at the factory.
SHOPTEK™ USER MANUAL SECTION 4 Figure 4-4: Fan Motor/Main Motor Rotational Direction ST400, ST500, ST700, 5-10HP 1. Main Motor Rotational Direction 2. Fan Motor Rotational Direction Figure 4-5: Fan Motor/Main Motor Rotational Direction ST1100, ST1500, 15-20HP 1. Main Motor Rotational Direction 2. Fan Motor Rotational Direction .
SHOPTEK™ USER MANUAL Section 5 OPERATION 5.1 ROUTINE OPERATION Before starting the compressor, check the fluid level in the separator tube. If sight glass is not completely full, add the required amount of fluid to bring it to its proper level. Frequent addition of fluid indicates the presence of a leak or a condition causing excessive fluid consumption. See the Troubleshooting – Introduction on page 66 under EXCESSIVE COMPRESSOR FLUID CONSUMPTION for a probable cause and corrective action.
NOTES 56 02250180-090 R00
SHOPTEK™ USER MANUAL Section 6 MAINTENANCE WARNING Before any repairs are attempted, refer to Section 1: Safety before proceeding. 6.1 GENERAL This compressor requires a minimal amount of inspections and maintenance. The Controller and other indicators alert the operator to situations requiring maintenance, or fault conditions. 6.2 MAINTENANCE AFTER INITIAL 50 HOURS OF OPERATION After the initial 50 hours of operation, maintenance is required to clean the system of any foreign materials.
SHOPTEK™ USER MANUAL SECTION 6 6.5 FILTER MAINTENANCE Refer to Figure 6-3. Replace the fluid filter under any of the following conditions, or whichever occurs first: 1. Every 2000 hours a display on the Controller indicates the need for replacement 2. Every fluid change. FLUID FILTER REPLACEMENT Refer to Figure 6-3. 1. Use a strap wrench to remove the filter and gasket. 2. Dispose of filter properly. 3. Clean gasket seating surface. 4. Apply a light film of fluid to the filter gasket. 5.
SECTION 6 6.6 SHOPTEK™ USER MANUAL AIR FILTER MAINTENANCE Refer to Figure 6-4 and Figure 6-5. Air filter maintenance should be performed every 2000 hours or sooner if necessary. AIR FILTER ELEMENT REPLACEMENT 1. Remove enclosure panels to gain access to filter. 2. Loosen hose clamp and remove filter. 3. Install new filter and tighten hose clamp. Figure 6-5: Air Filter Assembly 15-20HP 1. Air Filter Element 2. Clamp 3. Hose Figure 6-4: Air Filter Assembly 5-10HP 1. Air Filter Element 2. Clamp 3.
SHOPTEK™ USER MANUAL 6.7 SECTION 6 SEPARATOR MAINTENANCE Replace the separator elements every 2 years or 4000 hours, whichever occurs first. The separator elements must be replaced. DO NOT attempt to clean and reinstall the separator elements. SEPARATOR ELEMENT REPLACEMENT Refer to Figure 6-6. Use the following procedure below to change the separator: CAUTION Relieve all pressure from the separator/ sump tank and all compressor lines. 1.
SECTION 6 SHOPTEK™ USER MANUAL Belt tension must be re-adjusted 0.5 to 2 hours after a new set of belts are fitted. This will ensure that the belts have completed their initial stretch. Subsequent to this, belt tension needs to be checked and adjusted if necessary every 2000 hours for the duration of the belt life. There are two recommended methods for checking the belt tension. The test methods will be detailed as follows. BELT TENSION MEASUREMENT WITH OPTIKRIK TENSION METER. Refer to Figure 6-8.
SHOPTEK™ USER MANUAL SECTION 6 Figure 6-8: Optikrik Belt Tension Meter BELT TENSION MEASUREMENT WITH FREQUENCY METER G. Repeat for remaining belts. Refer to Figure 6-9. Follow instructions as follows: H. Compare the resuls to the belt tension specification in Table 6-1 and adjust if necessary. A. Turn on the meter. B. Hold the meter so that the probe is >10mm (3/8”) away from the belt being tested. Do not touch the belt with tester probe. C.
SECTION 6 SHOPTEK™ USER MANUAL Table 6-1: Belt Tension Requirements Model HP ST400 Series ST410 5 ST410 5 ST500 Series ST510 7.5 ST510 7.
SHOPTEK™ USER MANUAL SECTION 6 Figure 6-10: Belt Tension Adjustment, ST400, ST500, ST700, 5-10HP 64 1. Belt Guard 5. Comp. Unit Mounting Plate Bolts (4) 2. Belt Tension Adjustment Screw 6. Comp. Unit Pulley 3. Locking Nut 7. Belts 4. Jacking Nut 8.
SECTION 6 SHOPTEK™ USER MANUAL Figure 6-11: Belt Tension Adjustment, ST1100, ST1500, 15-20HP 6.9 1. Belt Guard 5. Comp. Unit Mounting Plate Bolts (4) 2. Belt Tension Adjustment Screw 6. Comp. Unit Pulley 3. Locking Nut 7. Belts 4. Jacking Nut 8. Motor Pulley REPLACEMENT AND ALIGNMENT OF BELT PULLEYS PARALLEL ALIGNMENT CAN BE CHECKED BY TWO METHODS. In the event of the motor or compressor unit having been removed and replaced, pulley alignment will have to be checked and adjusted.
SHOPTEK™ USER MANUAL SECTION 6 To correct parallel misalignment, first check that the rear face of the compressor unit pulley is positioned 0.3in (7.5mm) off the mounting face. This is required to ensure that the belts clear all mounting bolt heads. With the compressor unit pulley correctly positioned, move the motor pulley on the shaft to achieve correct alignment. 1 INSTRUCTIONS FOR INSTALLING A PULLEY: 1. Clean all surfaces of shaft, pulley and taper lock bushing.
SECTION 6 SHOPTEK™ USER MANUAL Table 6-3: Troubleshooting Guide SYMPTOM PROBABLE CAUSE REMEDY Compressor will not start Main disconnect switch open Close switch. Line fuse blown Replace fuse. Motor starter overload tripped Reset - if fault persists, check motor contacts for proper function. Low incoming line voltage Check voltage - in the case of low voltage, check power source, or contact local power company. Loss of control voltage Check 110V AC power supply.
SHOPTEK™ USER MANUAL SECTION 6 Table 6-3: Troubleshooting Guide SYMPTOM PROBABLE CAUSE REMEDY Compressor cannot produce full discharge pressure Air demand too high Check service lines for leaks or open valves. Dirty air filter Replace filter. Inlet valve bleed orifice obstructed/plugged Check the control line bleed orifice inside the inlet valve for blockage or obstructions.
NOTES 69
WORLDWIDE SALES AND SERVICE SULLAIR ASIA, LTD. SULLAIR CORPORATION SULLAIR EUROPE, S.A. Zuo Pao Tai Road, No. 1 Chiwan, Shekou Shenzen, Guangdong PRV. PRC POST CODE 518068 Telephone: 755-6851686 Fax: 755-6853473 www.sullair-asia.com 3700 East Michigan Boulevard Michigan City, Indiana, 46360 U.S.A. www.sullair.com Telephone: 1-800-SULLAIR (U.S.A. only) Fax: 219-874-1273 Zone Des Granges BP 82 42602 Montbrison, France Telephone: 33-477968470 Fax: 33-477968499 www.sullaireurope.