Product Manual
Page 8 of 16
Minimum Wire Size Of Extension Cords
Nameplate AMPS
Cord Length
25'
50'
100'
150'
0-6
18 AWG
16 AWG
16 AWG
14 AWG
6-10
18 AWG
16 AWG
14 AWG
12 AWG
10-12
16 AWG
16 AWG
14 AWG
12 AWG
12-16
14 AWG
12 AWG
NOT RECOMMENDED
• When using more than one extension cord to make up the total length, make sure each cord
contains at least the minimum wire size required.
• If you are using one extension cord for more than one tool, add the nameplate amperes and use
the sum to determine the required minimum cord size.
• If you are using an extension cord outdoors, make sure it is marked with the suffix W-A (W in
Canada) to indicate it is acceptable for outdoor use.
• Make sure your extension cord is properly wired and in good electrical condition. Always replace
a damaged extension cord or have it repaired by a qualified electrician before using it.
• Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.