Operating Instructions and Installation Instructions
ENGLISH
www.stiebel-eltron.com DHB-E SLi | 33
INSTALLATION
Installation options
13.12 Temperature limit / Anti-scalding protection
The maximum temperature can be limited to 43°C on the pro-
gramming unit of the appliance cover. For this, the following steps
are necessary:
Remove the appliance cover.
Remove the electronic PCB from the programming unit of the
appliance cover. Be careful with the snap-on hooks.
Move the plug from left to right (position "43°C").
Refit the programming unit, ensuring the snap-on hooks
click into place. Observe the positions of the push-button and
shaft.
CAUTION Burns
If operating the appliance with preheated water, the set
temperature limit and anti-scalding protection may be
ineffective.
In this case, restrict the temperature at the upstream
central thermostatic valve (see chapter "Installation/
Appliance description/ Accessories").
26�02�02�0833