Metering and Loudness (Cubase Pro only)
Loudness Measurement
Shows the average loudness measured from start to stop. The period of measurement
is shown in the Time display. The recommended value for the integrated loudness is -23
 LUFS. This absolute value is the reference point for the relative LU scale where -23 LUFS
equals 0 LU.
10 Range
Shows the dynamic range of the audio measured from start to stop. This value helps you
to decide how much dynamic compression you can apply. The range that is recommended
for highly dynamic audio such as film music is 20 LU.
11 True Peak
Shows the true peak level of the audio. The maximum permitted true peak level in
production is -1 dB.
12 Time
Shows the duration of the integrated loudness measurement.
RELATED LINKS
Displaying Meters on page 385
Control Room(Cubase Pro only) on page 371
Metering and Loudness (Cubase Pro only) on page 384
Loudness Settings
To open the Loudness Settings dialog, select Studio> Control Room> Meter>
Loudness> Configure Loudness Settings.
The following parameters are available:
1 Select Preset
Allows you to create, load, and remove loudness presets.
2 Momentary Max
Allows you to specify a reference value and a tolerance value for the maximum momentary
loudness. If higher values are detected, the clipping indicator in the loudness meter turns
red.
3 Short-Term
Allows you to specify a reference value and a tolerance value for the short-term loudness.
If higher values are detected, the clipping indicator in the loudness meter turns red.
4 Integrated
388