Plug-in Reference

Max.Value
Sets the measurement mode for the maximum level value display. The following
modes are available:
True Peak shows the estimated real peak value for each channel.
Peak Max. shows the maximum sample value for each channel.
RMS Max. shows the maximum RMS value for each channel.
RMS Max. + True Peak shows the highest maximum RMS and the highest
estimated real peak value of all channels.
RMS Max. + Peak Max. shows the highest maximum RMS and the highest
maximum sample value of all channels.
Level Histogram
This module shows a histogram for the peak or RMS value of the input level.
The following module-specic settings are available in the Module Settings window:
Scale
Allows you to select a scale according to different broadcast standards (Internal,
Digital, DIN, EBU, British, Nordic, K-20, K-14, K-12, +3 dB Digital, +6 dB Digital, or
+12 dB Digital).
Meter Mode
Sets the displayed level value.
Peak mode shows a histogram of the peak value.
RMS mode shows a histogram of the RMS value.
Peak Fallback
Sets the speed of release for the level meters and peak indicators.
NOTE
If you change this parameter during playback, you must click Reset Module
Values to update the display.
Alternatively, you can move the mouse pointer over the selected module, hold ,
and use the mouse wheel to adjust this parameter.
If this control is turned all the way to the left, the peak indicators are disabled.
Offset
Sets the offset between measured and displayed value in dB.
This parameter is only available for the DIN, EBU, British, and Nordic scale.
Included VST Audio Effect Plug-ins
SuperVision
43
Dorico 4.0.31