Specification Sheet

Specications
Features
Limited lifetime warranty - 2-year in home labor warranty where
available
Proportional Steam
Microprocessor based diagnostics and LED indication
Stainless Steel Tank Construction
Intelligent control communication
UL/CUL Listed
Required Equipment
TSC Control
Required Electrical Service
Dedicated circuit required: See Specification Chart for proper
electrical requirements
Product Information
Water Supply - ⅜" Compression Fitting, 120 PSI Max
Steam Outlet - ¾" Brass NPT male thread
Pressure Relief Valve - ¾" NPT female thread
Drain Outlet - Capped 1/2" Brass NPT male thread
Supplied with a 35’ control cable
Generator
Weight - 30 lbs.
Installation Notes
For optimum performance, the steam generator should be
mounted as close as possible to the steam room. If
needed, the steam pipe may be up to 50’ long.
Steam Generators should be accessible for service.
Do NOT install near flammable material such as paints,
thinners, gasoline, etc.
Steam generators must NOT be installed outdoors, in
moist, humid areas, in areas prone to freezing, or extreme
heat such as an unventilated attic. To do so will void the
warranty.
Steamhead to be mounted 12" to 18" above floor or 6"
above rim of tub and as far from the seating area as
possible.
Service Access
Minimum: 21" W x 18" D x 22" H (28" W with Auto Drain)
05/17
Pub. No. 234-B
Steam Generator Models: SMP-5, SMP-7 and SMP-10
- 1 -
Steam Generator Specication Chart
5
7.5
10
100
250
450
240/1/21
208/1/24
240/1/31
208/1/36
240/1/42
208/1/48
30
30
40
50
50
60
Product
Number
KW
Rating
Max. Cu. Ft.
Range*
Volts/Phase/
Max. Amps
Line
Fuse
15" x 6" x 15.5"
Dimensions
L x W x H
SMP-5
SMP-5-208
SMP-7
SMP-7-208
SMP-10
SMP-10-208
* Refer to sizing guidelines to accurately determine the proper size generator for the installation.
90°C copper wire is required for generator connection. Installation shall be in accordance with NEC and local electrical
codes.
®
Models: SMP-5, SMP-7 and SMP-10