Steam Outlet Pipe - Use a ¾" Copper or Brass pipe.
CAUTION: Do NOT install a shutoff valve on the steam outlet pipe. Do NOT create traps or valleys in this line which
would prevent the flow of steam. The steam outlet pipe should be pitched toward the Steam Generator (preferred),
allowing condensation to run back into the Steam Generator or toward the steamhead. If the steam pipe exceeds ten
feet, use an appropriate pipe insulation rated for a minimum of 212°F.
TSC model control
MUST be installed inside the
Steam room.
Steamhead Installation
Steamhead should be mounted 12”
to 18" above the finished floor or 6"
above the rim of the tub as far from
the bather as possible.
Safety Valve
Connect ¾" pipe to an
indirect waste or as
required by local codes.
Union
Required
Auto Drain Ready
½" Capped Line
The Plumbing Instructions must be given to the homeowner for future use.
⅜" Shutoff Valve
Keep in open
position during
normal operation.
Connect to Hot or
Cold water supply
Plumbing Installation Instructions
Figure 4 - Typical Installation Models: SMP-5, SMP-7, SMP-10, SM-12 and SMP-15