STEAM BATH GENERATOR USER GUIDE MODELS AUTO HI D DON’T WAIT! REGISTER NOW! Register your product within 90 days to ensure your steam bath generator is recognized as an official purchase and is eligible for warranty coverage. Mail in the completed registry card (Pg. 2) or register online at www.SteamSpa.com/register. Steam Spa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.com v3.9 ET IN RA EA T -IN W T UOUS S T TIN B UIL K S TA R CON Q UIC M 4.5KW 6KW 7.
PRODUCT REGISTRATION* IMPORTANT: Your warranty will not be recognized unless this card is fully completed and returned or online registration is completed. To ensure that your warranty is registered and confirmed please do one of the following: 1. Register online at www.SteamSpa.com/register. You will be asked to fill out the same information you would in the registration card. Registering online is fast, secure and ensures we receive your information. 2.
IMPORTANT WARRANTY INFORMATION! The installation of a quick release and pressure reduction system is essential to the care and maintenance of your steam bath generator unit. Additionally, the use of an inline water filter with fresh cartridges prevents mineral deposit and built up from damaging the generator’s internal plumbing and compnents. 1. The User must register product within 90 days of delivery. See www.SteamSpa.com/register. 2. Installation must be performed by a licensed professional. 3.
This peel-n-stick warning label must be applied to the wall of the shower or steam enclosure, at a point visible to all users. Failure to install sticker may result in serious injury or death. For replacement label contact SteamSpa at 1-800-856-0172 or info@steamspa.com. Steam Spa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
TABLE OF CONTENTS PROLOGUE..............................................................................................................................................6 USER INSTRUCTIONS ................................................................................................................................6 CHOOSING THE RIGHT LOCATION .................................................................................................................6 INSTALLATION DRAWING OF STEAM GENERATOR ...........
PROLOGUE Thank You for choosing SteamSpa for health, beauty and relaxation. Now you can enjoy your own private sanctuary in the comfort of your own home. Let your stress melt away as you relax in your state of the art Steam Room. WARRANTY SteamSpa warrants that this steam bath generator unit will be free from manufacturer defects and malfunctions. For terms and condition please refer to latest SteamSpa Warranty at www.SteamSpa.com/warranty.
INSTALLATION & USER GUIDE INSTALLATION DRAWING OF STEAM GENERATOR ATTENTION! The drawing is only for explanation purposes. As for practical design of steam room, please consult with a qualified designer, architect or builder. Page 7 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
INSTALLATION & USER GUIDE ATTENTION! The drawing is only for explanation purposes, please consult with a qualified designer, architect or builder. IMPORTANT! All pipe connections should have unions and adapters for easy disconnect. ATTENTION! Proper installation is a critical requirement per the SteamSpa Warranty terms and conditions. A licensed professional must be used to ensure proper installation. A quick release system, pressure reducing valve, inline water filter and regular maintenance are required.
The steam generator maybe installed in these location. 1. In closet located behind the shower. 2. In Attic 3. In basement etc. ATTENTION! If the installation of the steam generator will be more than 10 to 15 feet away from the steam room. It is recommended to increase the size of the generator 1 or 2 kilowatts higher to increase the steam flow. Page 9 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
PLUMBING INSTALLATION WARNING! The installation of all water supply lines should be in accordance to all national and local codes by a licensed plumber. 1. Use unions when connecting pipes. 2. Use brass pipes or copper pipe only. 3. Do not use black and galvanized or PVC pipes. ATTENTION! Please ensure a quick connect and release system in employed when installing steam generator to plumbing.
STEAM HEAD (3/4’’) ATTENTION! Steam Head and the steam outlet gets very hot, try to avoid installing the steam head in a position which will easily come into contact with the person bathing. 1. Install the steam head approximately 12 inches above the ground floor. If the steam room material is acrylic or non-heatresistant sheet, please consult with material manufacturer about steam room applications. 2. The steam head outlet should be installed face down. To prevent scalding bather with steam or water.
STEAM GENERATOR SPECIFICATIONS 395mm 304mm 142mm 43mm 32mm 302mm 266mm Safety valve Water inlet 188mm 151mm 206mm Steam outlet Water drainage 62mm 72mm Fuse for wire power supply C o n tr o lle r w ir e and light wire hole Power wire hole INSTALLATION & USER GUIDE Fuse for wire power supply 4.
535mm 435mm 234mm Steam outlet 35 0mm 34mm 273mm 183mm Water inlet 38 5mm Safety valve Water drainage Fuse for wire power supply Controller wire and light wire hole Power wire hole 10.5kW/12kW/15kW ATTENTION! To facilitate maintenance, keep the steam engine clean. If the information provided is limited, do not operate on the pipeline and electric equipment arbitrarily as shown in the figure for proportion. ELECTRICAL REQUIREMENTS ELECTRICAL SUPPLY CIRCUITRY 1.
Ty p e P owe r KW El e c t ri c i t y s upply (1PH) Ele c tr ic current (A) Specifications for power wire (AWG) D-450 4.5 240V 19 12 D-600 6 240V 25 10 D-750 7.5 240V 32 8 D-900 9 240V 38 8 D-1050 10.5 240V 44 6 D-1200 12 240V 50 6 The data provided above is for 240V single-phased motors. Install an independent circuit breaker between supply line and steam generator. Install a power disconnect within sight of steam generator to cut-off power when not in use.
WIRING DIAGRAM S u p p ly L2 L1 Wa te r L e ve l Se nsor G T o C ont rol P a ne l Red ( S h o r t P i n ) Bl ack ( L o n g P i n ) Yel l o w ( M i d d l e P i n ) T e rm i na l B l oc k J1 Red B lack Red Red Drain water valve Red S Red S Fill water valve Black White Black Red J1-2 Red Yellow R ed Black J1-1 Bla ck Ye l l ow / G re e n B lack R ed B lack R ed D- 450 S u p p ly L2 L1 Wa te r L e ve l Se nsor G INSTALLATION & USER GUIDE T o C ont rol P a ne l Red ( S h o r t P i n
S u p p ly Wa te r L e ve l Se nsor T o C ont rol P a ne l Red ( S h o r t P i n ) Bl ack ( L o n g P i n ) Yel l o w ( M i d d l e P i n ) G L2 L1 J1 T e rm i na l B l oc k Red Red J1-2 J2-2 J2-1 Black Red Black R ed J1-1 Black Yellow R ed Black Ye l l ow / G re e n B lack Red Red Red Drain water valve Red Red S Fill water valve B lack S Red J2 Black White Black B lack D-1050 R ed D-1200 L2 Wa te r L e ve l Se nsor L1 G T o C ont rol P a ne l Red ( S h o r t P i n ) Bl
STEAM GENERATOR DISSECTION DIAGRAM 2 1 14 16 3 17 15 4 13 12 6 INSTALLATION & USER GUIDE 5 11 10 7 8 9 1. 2. 3. 4. 5. 6. ENCLOSURE INSULATION BRACKET CIRCUIT BOARD STEAM OUTLET PRESSURE RELIEF VALVE WATER FILL VALVE 7. WATER DRAIN VALVE 8. SUBSIDIARY WATER TANK 9. MAIN WATER TANK 10. HEATING ELEMENT 11. 221 F HI-LIMIT 12. TRANSFORMER 13. TERMINAL BLOCK 14. FUSE 15. GROUND WIRE CONNECTOR 16. RELAY 17. WATER LEVEL SENSOR Page 17 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.
CARE & USE FOR THE CONTROL PANEL 1. Use soft cloth with a little soap water to clean the control panel. 2. Do not use crude cleaning tools. 3. If the decorating facade is damaged, contact service electrician to change it. Do not install any SteamSpa controls without reading and understanding the SteamSpa generator Installation and Instruction manual.
CONTROL PANEL INSTALLATION INSTRUCTIONS STEP ONE Determine the installation location of the control panel. The master control panel is designed to be installed in the steam room only, please install: 1. 4-5 feet from the ground. 2. Keep away from the steam head and do not expose under the direct spray of steam. 3. Install in the perpendicular wall. 4. The position of installation should facilitate easy operation and convenient wiring. The controller wire is 1.
TESTING THE MACHINE 1. Make sure the power switch of the control panel is turned on (the control panel displays ---), and the water supply valve will open. 2. The generator must be operating in order to turn the light on or off. (If light was purchased) 3. Press the button to start the steam, the steam will come out of the steam generator in 1 to 2 minutes depending on generator size.
CONTROL PANEL OPERATION The control panel has a digital temperature control system which can start, stop or pause in the preset time to keep the temperature at the set number. Fig.1 ON/OFF When system is powered, all functions will still not be activated and remain in a waiting state. Digital tube will display ---- (Fig.1). In the waiting state, press the button to turn on the system and activate steam function. System will recall last use steam time and TEMP, system begins to count down.
TESTING THE MACHINE 1. Press the power button, , and the control panel will display the room’s temperature and the water inlet valve will open up to allow the correct amount of water into the generator to begin producing steam. 2. The generator must be operating in order to turn the light on or off. (Light sold separately) 3. After starting the generator steam production will begin in a short while and will continue until the set temperature is reached.
CONTROL PANEL OPERATION The control panel has a digital temperature control system which can start, stop or pause in the preset time to keep the temperature at the set number. ON/OFF When system is powered, all functions will still not be activated and remain in a waiting state. Digital tube will display ---- . In the waiting state, press the button to turn on the system and activate steam function. System will recall last use steam time and TEMP, system begins to count down.
INSTALLATION OF CONTROL PANEL Installation of control panel and TEMP sensor Recess mount into wall 3.9 inches 5.6 inches INSTALLATION & USER GUIDE Open square notch by 3.9x5.6 inch to steam generator D sensor control panel Screw 3.9 feet to 4.5feet high from the ground Page 24 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
INSTALLATION OF CONTROL PANEL S tick on the wall drill a round hole 1.378 inches INSTALLATION & USER GUIDE to steam generator sensor control panel 4feet to 4.5feet high f rom the ground stick sealant Page 25 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
INSTALLATION OF TEMPERATURE SENSOR drill a round hole temperature sensor 0.4 inches IMPORTANT! Do not install temperature sensor on the same wall as the steam head to avoid a false reading. Can be placed on any other surface away from the steam head. Controller oof rating CONTROLLER SIZE AND WATERPROOF RATING Control panel model GS1090C(single panel) GS1090D(dual panel) Panel size ( length*width*height) 5.9x3.5x1 inches 5.9x3.
STEAM GENERATOR MAINTENANCE IMPORTANT! The steam generator automatically performs a water discharge operation after each use. 1. Wait for the completion of automatic water discharge after each time using the steam generator to make sure the water in the tank is discharged completely before cutting off power supply. 2. There should not be any leakage or damage among the steam generator, steam nozzle, components and pipes. They should be checked and repaired annually. 3.
TROUBLE SHOOTING POSSIBLE CAUSES SOLUTIONS The machine does not start when powered 1. Burned out fused 2. The electrical wiring became loose 3. Control panel connection loose Breakers are tripping 1. The wire connector is dampened or damaged 2. Damaged heating element 1. Replace fuse (0.8A/240V) 2. Cut power Supply and reconnect wiring 3. Reconnect control panel and reset 4. Controller (turn off and on) 1. Check whether the wire connector is dampened or damaged, and dry if dampened 2.
POSSIBLE CAUSES SOLUTIONS 1. The signal that transfers between the control panel and generator has a problem 1. Check the connection on the control cable to make sure all 13 pins are functional Receiving an error “E0” on the control panel 1. Lack of water in the tank. The water inlet valve is not turning on which is preventing water from entering 1.
Type Power (KW) Voltage (V) Current (A) Errors Range Anti-Static Constant Insulation Resistance Head Lamp Temperature Range (°F) Time Set Range (min) Steam Press (psi) Steam Vol. (cu. in./min) Steam Spray Time (sec) Water Vol. (cu. in.) 4.5KW 6KW 7.5KW 9KW 10.5KW 12KW 15KW 4.5 240 19 +10% >1500V >20M Ω ~12V/3W 50-130 1-60 3 9 100-180 80 6 240 25 +10% >1500V >20M Ω ~12V/3W 50-130 1-60 4 11 180-240 160 7.
WIRING DIAGRAMS 4.5KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V~ Page 31 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
6KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V Page 32 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
7.5KW & 9KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V~ Page 33 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
10.5KW & 12KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V Page 34 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
15KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V Page 35 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
SIZING CHART *Cabin Dimensions Cubic Feet Generator 3x3x7 63 4kw or 6kw 3x4x7 84 7kw or 9kw 3x5x7 105 9kw or 10.5kw 3x6x7 126 9kw or 10.5kw 3x7x7 147 10.5kw or 12kw 3x8x7 168 12kw 4x4x7 112 9kw 4x5x7 140 9kw or 10.5kw 4x6x7 168 10.