INSTALLATION & USER GUIDE
TECHNICAL PARAMETERS
Type
4.5KW 6KW 7.5KW 9KW 10.5KW 12KW 15KW
Power (KW) 4.5 6 7.5 9 10.5 12 15
Voltage (V) 240 240 240 240 240 240 240
Current (A) 19 25 32 38 44 50 63
Errors Range +10% +10% +10% +10% +10% +10% +10%
Anti-Static Constant >1500V >1500V >1500V >1500V >1500V >1500V >1500V
Insulation Resistance >20M Ω >20M Ω >20M Ω >20M Ω >20M Ω >20M Ω >20M Ω
Head Lamp ~12V/3W ~12V/3W ~12V/3W ~12V/3W ~12V/3W ~12V/3W ~12V/3W
Temperature Range (°F) 50-130 50-130 50-130 50-130 50-130 50-130 50-130
Time Set Range (min) 1-60 1-60 1-60 1-60 1-60 1-60 1-60
Steam Press (psi) 3 4 4 4 5 5 5
Steam Vol. (cu. in./min) 9 11 13 16 19 21 25
Steam Spray Time (sec) 100-180 180-240 150-210 120-180 170-230 150-160 120-150
Water Vol. (cu. in.) 80 160 160 160 330 330 330
Applicable Space of the
Room (cu. ft.)
90 150 225 300 400 450 500
IMPORTANT! The list above is for reference only. Actual checking and repairing should be based on national and local codes, ask
professional service personnel to operate.
IMPORTANT! The parameter listed above will vary by geographical location and environment. Please consult a qualified designer
and architect for more detailed use.