STEAM BATH GENERATOR USER GUIDE AUTO D v2.2 S P E R Q UI ET IN HI RA EA T Steam Spa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.com -IN W T UOUS S T TIN B UIL K S TA R CON UIC Q 4.5KW 6KW 7.5KW 9KW 10.
This peel-n-stick warning label must be applied to the wall of the shower or steam enclosure, at a point visible to all users. Failure to install sticker may result in serious injury or death. For replacement label contact SteamSpa at 1-800-856-0172 or info@steamspa.com. Steam Spa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
TABLE OF CONTENTS PROLOGUE........................................................................................................................4 USER INSTRUCTIONS..........................................................................................................4 CHOOSING THE RIGHT LOCATION...........................................................................................4 INSTALLATION DRAWING OF STEAM GENERATOR......................................................................
PROLOGUE Thank You for choosing SteamSpa for health, beauty and relaxation. Now you can enjoy your own private sanctuary in the comfort of your own home. Let your stress melt away as you relax in your state of the art Steam Room. For Centuries people have recognized the health benefits of saunas. Leave your stress behind and enter a world of total relaxation, ridding you of pain, toxins, and sore muscles as well as increasing your blood circulation etc., leaving your skin glowing.
INSTALLATION & USER GUIDE INSTALLATION DRAWING OF STEAM GENERATOR ATTENTION! The drawing is only for explanation purposes. As for practical design of steam room, please consult with a qualified designer, architect or builder. Page 6 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
INSTALLATION & USER GUIDE ATTENTION! The drawing is only for explanation purposes , please consult with a qualified designer, architect or builder. Page 7 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
The steam generator maybe installed in these location. 1. In closet located behind the shower. 2. In Attic 3. In basement etc. ATTENTION! If the installation of the steam generator will be more then 10 to 15 feet away from the steam room. It is recommended to increase the size of the generator 1 or 2 kilowatts higher to increase the steam flow. Page 8 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
PLUMBING INSTALLATION WARNING! The installation of all water supply lines should be in accordance to all national and local codes by a licensed plumber. 1. Use unions when connecting pipes. 2. Use brass pipes or copper pipe only. 3. Do not use black and galvanized or PVC pipes. WATER SUPPLY PIPE (1/2’’) STEAM PIPE (3/4’’) 1. Do not install any stop valves in the steam pipes. The steam can never be obstructed. 2. Install a 3/4” copper or brass pipe between the steam generator and the steam nozzle. 3.
DRAINPIPE (1/2’’) ACCORDING TO THE NATIONAL AND LOCAL PLUMBING CODES: The steam generator drain valve should be equipped with a drainpipe. The steam generator drains the water by gravity.Check local code requirements for drain valves. Do not connect the safety valve or steam line to drain line. SAFETY VALVE (3/4’’) INSTALLATION & USER GUIDE 1. Safety valve is an automatic system that is actuated by pressure in order to prevent steam pressure increasing in the interior of the generator . 2.
STEAM GENERATOR SPECIFICATIONS 395mm 304mm 142mm 43mm 266mm 302mm Safety valve Water inlet 32mm 188mm 151mm 206mm Steam outlet Water drainage 62mm 72mm Fuse for wire power supply C o n tr o lle r w ir e and light wire hole Power wire hole INSTALLATION & USER GUIDE Fuse for wire power supply 4.
535mm 435mm 234mm Steam outlet 34mm 35 0mm 273mm 183mm Water inlet 38 5mm Safety valve Water drainage Fuse for wire power supply Controller wire and light wire hole Power wire hole 10.5kW/12kW/15kW ATTENTION! To facilitate maintenance, keep the steam engine clean. If the information provided is limited, do not operate on the pipeline and electric equipment arbitrarily as shown in the figure for proportion. ELECTRICAL REQUIREMENTS ELECTRICAL SUPPLY CIRCUITRY 1.
Ty p e Ap p licab le s p ace o f the room (cu.Ft. *) P owe r KW El e c t ri c i t y s upply (1PH) Ele c tr ic current (A) Specifications for power wire (AWG) S450 90 4.5 240V 19 12 S600 150 6 240V 25 10 S750 225 7.5 240V 32 8 S900 300 9 240V 38 8 S1050 400 10.5 240V 44 6 S1200 450 12 240V 50 6 The data provided above is for 240V single-phased motors. Install an independent circuit breaker between supply line and steam generator.
WIRING DIAGRAM S u p p ly Wa te r L e ve l Se nsor T o C ont rol P a ne l Red ( S h o r t P i n ) Bl ack ( L o n g P i n ) Yel l o w ( M i d d l e P i n ) B lack R ed S u p p ly T o C ont rol P a ne l J2 Black White Drain water valve Red Red Fill water valve B lack Red J1-2 Red Red Red Red S Black J1-1 Black Yel low R ed Black T e rm i na l B l oc k Ye l l ow / G re e n J1 B lack R ed G Black J2-1 Blac k Red ( S h o r t P i n ) Bl ack ( L o n g P i n ) Yel l o w ( M i d d l e P i n )
S u p p ly T o C ont rol P a ne l G T e rm i na l B l oc k J1 Red R ed S1200 L2 T o C ont rol P a ne l T e rmi na l B l oc k J1 INSTALLATION & USER GUIDE Red J3-2 B lack Red J2 Black White B lack Red Red Drain water valve J3-1 Black Red Red Red Fill water valve Bl ack J1-1 Black R ed Black S J2-1 Black Ye l l ow / G re e n Black Bl ack Yellow B lack R ed Red Red Red ( S h o r t P i n ) Bl ack ( L o n g P i n ) Yel l o w ( M i d d l e P i n ) Red Red Wa te r L e ve l Se nsor
STEAM GENERATOR DISSECTION DIAGRAM 2 1 14 16 3 17 15 4 13 12 6 7 11 INSTALLATION & USER GUIDE 5 10 8 9 1. 2. 3. 4. 5. 6. ENCLOSURE INSULATION BRACKET CIRCUIT BOARD STEAM OUTLET PRESSURE RELIEF VALVE WATER FILL VALVE 7. WATER DRAIN VALVE 8. SUBSIDIARY WATER TANK 9. MAIN WATER TANK 10. HEATING ELEMENT 11. 221 F HI-LIMIT 12. TRANSFORMER 13. TERMINAL BLOCK 14. FUSE 15. GROUND WIRE CONNECTOR 16. RELAY 17.
CARE & USE FOR THE CONTROL PANEL 1. Use soft cloth with a little soap water to clean the control panel. 2. Do not use crude cleaning tools. 3. If the decorating facade is damaged, contact service electrician to change it. Do not install any SteamSpa controls without reading and understanding the SteamSpa generator Installation and Instruction manual.
CONTROL PANEL INSTALLATION INSTRUCTIONS STEP ONE Determine the installation location of the control panel. The master control panel is designed to be installed in the steam room only, please install: 1. 4-5 feet from the ground. 2. Keep away from the steam head and do not expose under the direct spray of steam. 3. Install in the perpendicular wall. 4. The position of installation should facilitate easy operation and convenient wiring. The controller wire is 1.
TESTING THE MACHINE 1. Make sure the power switch of the control panel is turned on (the control panel displays ---), and the water supply valve will open. 2. Press the steam switch, , the control panel will display the temperature of the environment, the steam engine begins to input water to start the steam function, and while opening the steam, press the button to open light function. 3. When there is steam output, press again, the steam will stop and the light will go off automatically. 4.
CONTROL PANEL OPERATION The control panel has a digital temperature control system which can start, stop or pause in the preset time to keep the temperature at the set number. Fig.1 ON/OFF When system is powered, all functions will still not be activated and remain in a waiting state. Digital tube will display ---- (Fig.1). In the waiting state, press the button to turn on the system and activate steam function. System will recall last use steam time and TEMP, system begins to count down.
TESTING THE MACHINE 1. Press the power button, , and the control panel will display the room’s temperature and the water inlet valve will open up to allow the correct amount of water into the generator to begin producing steam. 2. The generator must be operating in order to turn the light on or off. (Light sold separately) 3. After starting the generator steam production will begin in a short while and will continue until the set temperature is reached.
CONTROL PANEL OPERATION The control panel has a digital temperature control system which can start, stop or pause in the preset time to keep the temperature at the set number. ON/OFF When system is powered, all functions will still not be activated and remain in a waiting state. Digital tube will display ---- . In the waiting state, press the button to turn on the system and activate steam function. System will recall last use steam time and TEMP, system begins to count down.
INSTALLATION OF CONTROL PANEL GS08A Installation of control panel and TEMP sensor Recess mount into wall 3.9 inches 5.6 inches INSTALLATION & USER GUIDE drill a round hole to steam generator D sensor control panel Screw 3.9 feet to 4.5feet high from the ground Page 23 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
INSTALLATION OF CONTROL PANEL G S 8A ol panel and TEMP sensor S tick on the wall drill a round hole 1.378 inches INSTALLATION & USER GUIDE to steam generator sensor control panel 4feet to 4.5feet high f rom the ground stick sealant Page 24 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
S08A INSTALLATION OF TEMPERTURE SENSOR Installation of control panel and TEMP sensor drill a round hole temperature sensor 0.4 inches temperature sensor holder IMPORTANT! Do not install temperature sensor on the same wall as the steam head to avoid a false reading. Can be placed on any other surface away from the steam head. Controller oof rating CONTROLLER SIZE AND WATERPROOF RATING Control panel model GS1090C(single panel) GS1090D(dual panel) Panel size ( length*width*height) 5.9x3.
STEAM GENERATOR MAINTENANCE IMPORTANT! The steam generator automatically performs a water discharge operation after each use. 1. Wait for the completion of automatic water discharge after each time using the steam generator to make sure the water in the tank is discharged completely before cutting off power supply. 2. There should not be any leakage or damage among the steam generator, steam nozzle, components and pipes. They should be checked and repaired annually. 3.
PROBLEM POSSIBLE CAUSES SOLUTIONS The machine does not start when powered 1. Burned out fused 2. The electrical wiring became loose 3. Control panel connection loose Breakers are tripping 1. The wire connector is dampened or damaged 2. Damaged heating element 1. Replace fuse (0.8A/240V) 2. Cut power Supply and reconnect wiring 3. Reconnect control panel and reset 4. Controller (turn off and on) 1. Check whether the wire connector is dampened or damaged, and dry if dampened 2.
POSSIBLE CAUSES SOLUTIONS 1. The signal that transfers between the control panel and generator has a problem 1. Check the connection on the control cable to make sure all 13 pins are functional Receiving an error “E0” on the control panel 1. Lack of water in the tank. The water inlet valve is not turning on which is preventing water from entering 1.
Type Power (KW) Voltage (V) Current (A) Errors Range Anti-Static Constant Insulation Resistance Head Lamp Temperature Range (°F) Time Set Range (min) Steam Press (psi) Steam Vol. (cu. in./min) Steam Spray Time (sec) Water Vol. (cu. in.) Applicable Space of the Room (cu. ft.) 4.5KW 6KW 7.5KW 9KW 10.5KW 12KW 15KW 4.5 240 19 +10% >1500V >20M Ω ~12V/3W 50-130 1-60 3 9 100-180 80 6 240 25 +10% >1500V >20M Ω ~12V/3W 50-130 1-60 4 11 180-240 160 7.
WIRING DIAGRAMS 4.5KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V~ Page 30 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
6KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V Page 31 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
7.5KW & 9KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V~ Page 32 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
10.5KW & 12KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V Page 33 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
15KW INSTALLATION & USER GUIDE Control panel(outside room) Control panel(inside room) 240V Page 34 SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.
AUTO D HI S P E R Q UI ET IN RA EA T Steam Spa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.