RV Series Installation Instructions IN009 Rev P 0423 3 Saber Way, Ward Hill, MA 01835 | radonaway.
Fan Installation & Operating Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE TO FAN IS LOCKED IN “OFF” POSITION. DISCONNECT POWER BEFORE SERVICING FAN. 1. WARNING! For General Ventilating Use Only. Do Not Use to Exhaust Hazardous, Corrosive or Explosive Materials, Gases or Vapors. See Vapor Intrusion Application Note #AN001 for important information on VI Applications. See RadonAway.com/vapor-intrusion. 2.
Fan Installation & Operating Instructions Fan Series RV100 p/n 28040 RV125 p/n 28042 RV150 p/n 28041 RV200 p/n 28049 1.0 MOUNTING The Spruce RV Series Fans may be mounted at any angle without affecting performance although the vertical mounting position shown in Fig. 1 is highly recommended. If the vertical mounting position is not possible, care should be taken to avoid creating a low spot in the fan/duct system where condensation might accumulate in the fan housing as shown in Fig. 2.
.0 BACKDRAFT DAMPERS Backdraft dampers allow airflow in only one direction preventing cold/hot drafts from entering the vented area and minimize possible condensation and icing within the system while the fan is not operating. Backdraft dampers are highly recommended at each intake grille for bathroom ventilation in all cold climate installations. Installation instructions are included with Spruce backdraft dampers. 5.
Step 6: Make electrical connection to fan (Fig. 9). Ensure any metal filing used in the installation is properly grounded. A plastic cable connector such as a T&B #3300 may be used to avoid any filing grounding problem. Observe the proper wiring connections (See Section 5.0). Note that the fan is not intended for connection to rigid metal conduit. RV Series Wire AC Connection Black AC Line White AC Common Green or Grn/Ye Ground 7.0 INSTALLATION FIGURES Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig.
RV SERIES PRODUCT SPECIFICATIONS The following chart shows fan performance for RV Series Commercial/Residential Fans: Typical CFM vs. Static Pressure "WC 0" .2" .5" .75" 1.0" 1.25" 1.5" Max Static Pressure RV100 101 90* 66* 41 15* - - 1.06" WC RV125 118 110* 95* 82 65* 49 33 2.00" WC RV150 141 130* 109* 90 70* 43 18 1.80" WC RV200 175 160* 139* 115 78* 32 - 1.40" WC *Denotes HVI Certified Values. Power Consumption @ 120 VAC, 60Hz (1.
IN009 Rev P 0423 3 Saber Way, Ward Hill, MA 01835 | radonaway.com 7 Optimal T or Y for Second Vent RV Series Fan Insulated Ducting is strongly recommended in colder climates Flexible Duct Mounting Bracket Included -RV200 – P/N 28049 -RV150 – P/N 28041 -RV125 – P/N 28042 -RV100 – P/N 28040 RV Series Fans Vent Details 5 Backdraft Dampers are strongly recommended in colder climates.
IMPORTANT INSTRUCTIONS TO INSTALLER Inspect the RV Series Fan for shipping damage within 15 days of receipt. Notify Spruce of any damages immediately. Spruce is not responsible for damages incurred during shipping. However, for your benefit, Spruce does insure shipments. There are no user serviceable parts inside the fan. Do not attempt to open. Return unit to factory for service. Install the RV Series Fan in accordance with all state and local building codes and state regulations.