Brochure

Page 10 / Bulletin 30-10
Types B9 and E9 Series 22, 134a, 401A, 402A, 404A, 407C, 502, 507
EVLAV
SEIRES
EPYT
DRADNATS
SNOITCENNOC
sehcnI
TROP
EZIS
sehcnI
DPOM
isp
SEITICAPACDIUQILLANIMON
noitaregirfeRfosnoT
SGNITARLIOC
STNAREGIRFER
22 a431 A104 A204 A404 C704 205 705
porDerusserP isp
CA CD 3 2 2 3 3 3 3 3
DRADNATS
SELCYC/STLOV
STTAW
CA CD
9B
2P9B 8/3 TPN elameF
23/9
003 052
1.8 2.6 6.6 3.5 4.5 4.7 2.5 2.5
06-05/42
06-05/021
06-05/042-802
06-05/042-802-021
51 81
2S9B
MDO8/5-FDO2/1
003 052
2S9BM
2S9BO 572
2F9B
eralFEAS8/3 003 052
2F9BM
9E
032S9E
FDO8/3XFDO8/3
003 052
032S9EM
032S9EO
042S9E
FDO2/1XFDO2/1
042S9EM
042S9EO 572
052S9EM
FDO8/5XFDO8/5
003 052
052S9EO 572
Type MB9S2
Normally Closed
Type E9S240
Normally Closed
Type OB9S2
Normally Open
n
Maximum rated pressure 500 psi.
n
Dual voltage 4-wire coils, 120-208-240/50-60 are available at slight additional cost. For
other voltages and cycles, consult Sporlan, Washington, MO 63090.
n
See Pages 19 and 20 for water and steam valves.
n
Available with conduit boss or junction box at no extra charge.
n
For capacity at other pressure drops, see Pages 4 and 5.
n
For mounting holes and/or bracket information see Bulletin 30-11.
n
E9 series with mounting holes are NOT standard.
1.75 Coil
Removal
3.17
A
D
*B
E
C
E9
SERIES
1.75 Coil
Removal
3.17
A
D
*B
D'
C
1.89
Optional 1/2” Conduit Boss
B9
SERIES
and Listed
Approved
Application
Types B9 and E9 Series are compact solenoid
valves with pilot operated disc construction for re-
frigeration and air conditioning. These valves may
be mounted horizontally, on their side or in
a vertical line. These valves are also suitable for
suction line service because very low pressure differ-
ential, 1 psi, is required for full operation.
The Type E9 series solenoid valves feature extended
solder type connections as standard. One important
benefit to the user is that all valves in the “E9” series
can be installed without disassembly using either low
or no silver content brazing alloy.
The MKC-2 and OMKC-2 coils are Class “F” tempera-
ture rated and are provided as standard, therefore a high
temperature coil is not required for discharge service.
Ordering Instructions
When ordering complete valves, specify Valve Type,
Connections, Voltage and Cycles.
When ordering Body Assembly, specify Valve Type
and Connections.
When ordering Coil Assembly ONLY, specify Coil
Type, Voltage and Cycles.
Example: MKC-2 120/50-60; OMKC-2 120/50-60.
Dimensions Inches
¸
EPYT A B*
C D 'D E
GNITTIF
HTPED
9B
2P9B 60.2
65.0 57.2 63.3
2S9B 88.2 05.0
2F9B 88.2
9E
032S9E 36.4 18.0 56.2 42.3 13.0
83.0
042S9E 00.5 57.0 07.2 03.3 83.0
13.0
052S9E 05.6 96.0 42.2 33.3 05.0
VALVE
SERIES
ODF
OFFSET
ODM
NORMALLY
CLOSED
NORMALLY
OPEN
*Add 1.12” for Valves with Manual Lift Stem.
Specifications MKC-2 and OMKC-2 Coil