Installation Sheet

INSTRUCTIONS FOR MODELS
92-CPV-TP-01
For additional assistance or service please contact:
SPEAKMAN
®
Company
400 Anchor Mill Road
New Castle, DE 19720
800-537-2107
customerservice@speakman.com
www.speakman.com
CPV-TP
CPV-TP-DV
HELPFUL TOOLS & SUPPLIES:
TOOLS AND SUPPLIES
Pencil Keyhole
Saw
Adjustable
Wrench
Thread Seal
Tape
9/16”Deep Well
Socket
Socket
Wrench
Solder Kit
Phillips
Screwdriver
Measuring
Tape
Safety
Glasses
Tubing
Cutter
13/16”Deep Well
Socket
Level
Additional warranty information can be found at:
www.speakman.com
WARRANTY
Your new Shower/Bath Valve is designed for years of
trouble-free performance. Keep it looking new by
cleaning it periodically with a soft cloth. The use of
harsh chemicals and abrasives on any of the Speakman
custom finish products may damage the finish and void
the product warranty. Please be sure to only use
approved cleaners. Please contact Speakman for any
clarification of acceptable cleaners.
MAINTENANCE
Cover your drain to prevent loss of parts. Be sure to
wear eye protection while cutting pipe.
SAFETY TIPS
IMPORTANT
• Be sure to read instructions thoroughly before
beginning installation.
• Be sure to have properly adjusted the Temperature
Limiting Stop (TLS) as outlined in this Installation
Manual.
• Inspect all connections after installation of valve.
• This valve has an operating range of 20-80 Psi.
• This valve is designed to be used in conjunction
with a shower-head rated at 1.5 gpm (5.7 L/min)
or higher flow rate.
NOTE: This installation manual covers several
models of valves. While the appearance of your
valve may differ from those shown, the installation
method is the same.
• Maximum water pressure: 125 PSI static; minimum
water pressure: 20 PSI flowing; minimum cold
supply temperature: 40° F; maximum hot supply
temperature: 160° F; minimum hot supply
temperature: 5° F above set point.
This type of valve must be cleaned and maintained on a
regular basis. Periodic maintenance should be
performed at least every 12 months or after any
changes have been made to the building’s plumbing
system. This maintenance should include removing and
cleaning the spring check stop components. Make sure
the stop poppet in each stop moves freely. The Lower
Cartridge Seal with Integral Screens (located at the base
of the Valve Cartridge) should be removed and cleaned
during this maintenance cycle.Valves that are installed
outdoors should be winterized by removing all of the
internal parts and removing any standing water from the
valve. Quarterly the maximum hot temperature setting
(TLS) should be checked and adjusted accordingly.
1
Referencing the supplied rough-in dimensions
(located at the end of this manual), determine the
preferred location of valve. Align the supplied
rough-in template with this location and trace
outline of template onto wall.
1’-9” (533mm)
TO CENTERLINE
OF TUB SPOUT
(FOR TUB INSTALLATION)
4’-6” (1.4m)
TO FLOOR
(SHOWER INSTALLATION)
2
Using a keyhole saw or similar tool, cut along
traced line and remove this section of wall.
3
Unthread and remove the Integral Stops using
a socket wrench equipped with a 9/16” deep
well socket.
Socket
Wrench
9/16”Deep Well
Socket
+
4
If your Shower Valve is equipped with an
integral diverter, remove the Diverter Nut using
a socket wrench and a 13/16” deep well
socket. Remove Diverter Cartridge to prevent
damage during soldering.
Socket
Wrench
+
13/16”Deep Well
Socket
5
Install the Rough-In Template over the Shower Valve being sure the Rough-In Template sits flush against Shower Valve Bonnet. Following the rough-in
dimensions for your model of valve (located ot the end of this manual) as well as the markings on the supplied rough-in template, install valve at proper
depth. The distance from the centerline of the inlet/outlet ports of the valve assembly to the finished wall MUST be between 2½” - 3½”. See images below
for reference.
SHOWER OUTLET
TUB OUTLET
ROUGH-IN TEMPLATE
THE BACK EDGE OF THE
ROUGH-IN TEMPLATE IS
FLUSH WITH OR INSIDE
THE VALVE ACCESS HOLE.
FINISHED WALL SURFACE
2½” MINIMUM
MOUNTING DEPTH
MINIMUM MOUNTING DEPTH
SHOWER OUTLET
TUB OUTLET
ROUGH-IN TEMPLATE
THE FRONT SURFACE OF
THE ROUGH-IN TEMPLATE
IS FLUSH WITH OR OUTSIDE
THE VALVE ACCESS HOLE.
FINISHED WALL SURFACE
3½” MAXIMUM
MOUNTING DEPTH
MAXIMUM MOUNTING DEPTH