Operation Manual

Vi5000/7000 User Manual
18.1: HiQnet CONFIGURATION
®
18.1: HiQnet SYSTEM CONFIGURATION
VM ² > HiQnet SYSTEM CONFIGURATION
The picture shows a typical AKG / HiQnet VM
2
set up. Shure systems can be connected directly to the Ethernet switch
and both Shure and AKG systems can be connected at the same time. If only one console is being used, and there is
no other HiQnet or Ethernet-connected equipment, the Hub4000Q can be directly connected to the console without
using a switch, but in most cases it is better to use one. A computer running HiQnet System Architect software may
also be connected to the switch, and if a wireless router is included in the network, the AKG wireless iPhone app may
be used for additional monitoring of the microphone data. The same wireless router or access point can be used to
connect the ViSi Remote iPad app for remote control of the console.
Setup of the console involves basic network setup (console IP address and HiQnet Node/Device ID) and assignment
of detected devices to the physical inputs they are connected to.