User Manual
Confidential
USERS MANUAL
41(41)
Document number Revision
4/198 17-LXE 108 566 Uen PA6
6 Technical Data
Mechanical specifications
Maximum length:
114 mm
Maximum width:
49.50 mm
Maximum thickness:
18.97 mm
Weight:
68.2 g
Power supply voltage, normal operation
VCC_MAIN
VCC_AUX
Nominal Voltage:
5.00 Volts
13.8 Volts
Voltage range:
4.50 – 5.50 Volts 11.0 – 16.5 Volts
Radio specifications
AMPS CDMA (BC-0) CDMA (BC-1)
Frequency range:
TX: 824 – 849
RX: 869 – 894
TX: 824 – 849
RX: 869 – 894
TX: 1850-1910
RX: 1930-1990
Antenna impedance:
50 50 50
VSWR (Maximum):
2:1 2:1 2:1
Environmental specifications
Operating temperature range:
-30°C to +70°C: EIA/TIA/IS-2000
+70°C to +85°C: –3dB Degradation beyond +70°C Spec
Storage temperature range:
-40
0
C to +85
0
C
Maximum relative humidity:
95% ± 3% at +40
0
C
Stationary vibration, random
Acceleration spectral density (m
2
/s
2
): 0.96 2.88 0.96
Frequency range: 5-10 10-200 200-500
60 min per/axis
Non-stationary vibration, including shock
Shock response spectrum I, peak acceleration:
- 3 shocks in each axis and direction: 300 m/s
2
, 11 ms
Shock response spectrum II, peak acceleration:
- 3 shocks in each axis and direction: 1000 m/s
2
, 6 ms
Bump:
Acceleration 250 m/s
2
Free fall transportation:
1.0 m
Rolling pitching transportation:
Angle: 35 degrees, period: 8s
Static load:
10 kPa
Low air pressure/high air pressure:
70 kPa / 106 kPa