If self-learning is correct, OK is displayed on the motorisation screen.
If self-learning has failed, KO is displayed on the motorisation screen. Check the following before restarting self-learning:
the gate runs correctly,
there is nothing obstructing the photoelectric cells (if tted).
If self-learning is interrupted, return the gate to the closed position and restart self-learning.
If the slowing down speed is subsequently changed, self-learning must be carried out again.
AT THIS STAGE IN THE INSTALLATION, THE MOTORISATION IS OPERATIONAL.
See pages 2 and 3 in the user’s manual.
24 V integrated ashing amber light
(ref. 9 014 552)
Photoelectric cells
With autotest Without autotest
24V
ac/dc
0V C NC NO
12345
12
24V
ac/dc
0V
CR
CE
24V
ac/dc
0V C NC NO
12345
12
24V
ac/dc
0V
CR
CE
Activate the cell autotest function: tESt Phot to ON in the LoGIc
menu.
Deactivate the cell autotest function: tESt Phot to OFF in the LoGIc
menu.