User's Manual

Confidential & Proprietary 36/48
3.1.5 HROU Power Cabling
AC Power
HROU supports AC110V/220V of input power. Provided outside power cable is only one type with
AWG#14 3m. Power cable is provided without power plug and it should be attached power plug based on
national’s power plug type.
The pin discription of AC port is below. You should connect exact polarity of AC.
Port outlook MS Connector numbering Name Description
A AC_H AC Hot
B AC_N AC Neutral
C N.C Not Connected
D F.G Frame Ground
Check if the connection is the same as one seen in the table above and make sure to turn the power ON.
Provided AC power cable’s outlook is below
DC Power
HROU supports only DC48V of input power. Provided outside power cable is only one type. The pin
discription of DC port is below. You should connect exact polarity of DC.
Port outlook MS Connector numbering Name Description
A N.C Not Connected
B N.C Not Connected
C +V +48V
D -V -48V
Check if the connection is the same as one seen in the table above and make sure to turn the power ON.
A : AC_H
B : AC_N
C : N.C
D : F.G