Installation Manual

Backup Power Only - System Configurations
26
To configure the inverters:
Configure the battery and backup power of both inverters as described in the Basic Configuration on page 20..
To verify communication:
Verify communication of both inverters as described in the Basic Configuration on page 21.
AC Coupling using a non-SolarEdge Inverter
For sites with an already installed PV system with a non-SolarEdge inverter, the StorEdge inverter can be AC-coupled to the
existing inverter, i.e. the StorEdge inverter used to manage the battery is connected to the AC output of the existing inverter and
charges the battery using the PV power produced by the non-SolarEdge inverter.
NOTE
The non-SolarEdge inverter production is not measured. The production information in the moniotring portal does not
take into account this production.
Figure 20: Backup Power Only - AC Coupling using a non-SolarEdge Inverter
To configure the system:
1 Configure the battery and backup power of the StorEdge inverter as described in the Basic Configuration on page 20.
To verify the communication:
Verify communication as described in the Basic Configuration on page 21.