SE9K SetApp Enabled Specifications

Three Phase Inverters for the 120/208V Grid
(1)
for North America
(1) For 277/480V inverters refer to:https://www.solaredge.com/sites/default/les/se-three-phase-us-inverter-277-480V-setapp-datasheet.pdf
(2) For other regional settings please contact SolarEdge support
(3) Where permitted by local regulations
(4) Field replacement kit for 1 pair of inputs P/N: DCD-3PH-1TBK; Field replacement kit for 3 pairs of fuses and holders P/N: DCD-3PH-6FHK-S1
(5) For power de-rating information refer to: https://www.solaredge.com/sites/default/les/se-temperature-derating-note-na.pdf
MODEL NUMBER SE9KUS SE14.4KUS
APPLICABLE TO INVERTERS
WITH PART NUMBER
SEXXK
-
XXXXXBXX4
OUTPUT
Rated AC Power Output 9000 14400 VA
Maximum AC Power Output 9000 14400 VA
Output Line Connections
3 phase, 3-wire / PE (L1-L2-L3), TN, TT
3 phase, 4-wire / PE (L1-L2-L3-N), TN, TT
AC Output Voltage Minimum-Nominal-Maximum
(2)
(L-N) 105-120-132.5 Vac
AC Output Voltage Minimum-Nominal-Maximum
(2)
(L-L) 183-208-229 Vac
AC Frequency Min-Nom-Max
(2)
59.3 - 60 - 60.5 Hz
x. Continuous Output Current (per Phase) 25 40 A
GFDI Threshold 1 A
Utility Monitoring, Islanding Protection, Country Congurable
Set Points
Yes
THD ≤ 3 %
INPUT
Maximum DC Power (Module STC) 12150 19400 W
Transformer-less, Ungrounded Yes
Maximum Input Voltage DC to Gnd 250 300 Vdc
Maximum Input Voltage DC+ to DC- 500 600 Vdc
Nominal Input Voltage DC to Gnd 200 Vdc
Nominal Input Voltage DC+ to DC- 400 Vdc
Maximum Input Current 26.5 38 Adc
Maximum Input Short Circuit Current 45 Adc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 1MΩ Sensitivity 350kΩ Sensitivity
(3)
CEC Weighted Efciency 96.5 97 %
Night-time Power Consumption < 3 < 4 W
ADDITIONAL FEATURES
Supported Communication Interfaces RS485, Ethernet, Built-in Cellular (Optional)
Inverter Commissioning With the SetApp mobile application using built-in Wi-Fi access point for local connection
Rapid Shutdown – NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect
RS485 Surge Protection Plug-in Supplied with the inverter
Smart Energy Management Export Limitation
STANDARD COMPLIANCE
Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07
Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI)
Emissions FCC part15 class B
INSTALLATION SPECIFICATIONS
AC output conduit size / AWG range 3/4” minimum / 8-4 AWG
DC input conduit size / AWG range 3/4” minimum / 12-6 AWG
Number of DC inputs 2 pairs 3 pairs
(4)
Dimensions (H x W x D) 21 x 12.5 x 10.5 / 540 x 315 x 260 in / mm
Dimensions with Safety Switch (H x W x D) 30.5 x 12.5 x 10.5 / 775 x 315 x 260 in / mm
Weight 99.5 / 45 lb / kg
Weight with Safety Switch 106 / 48 lb / kg
Cooling Fans (user replaceable)
Noise < 55 dBA
Operating Temperature Range -40 to +140 / -40 to +60
(5)
˚F / ˚C
Protection Rating NEMA 3R
SE9KUS / SE14.4KUS