SE43.2K Inverter Installation

RJ45 Pin #
Wire Color
(1)
10Base-T Signal
100Base-TX Signal
T568B T568A
5 White/Blue White/Blue Reserved
6 Green Orange Received-
7 White/Brown White/Brown Reserved
8 Brown Brown Reserved
Figure 36: Standard cable wiring
5. Use a pre-crimped cable to connect via the gland to the RJ45 port on the inverter's
communication board or, if using a spool of cable, connect as follows:
a.
Insert the cable through the gland.
Figure 37: Inserting communication cables
b. Remove the cable’s external insulation using a crimping tool or cable cutter and
expose eight wires.
c. Insert the eight wires into an RJ45 connector, as described
Figure 36
.
d. Use a crimping tool to crimp the connector.
e. Connect the Ethernet connector to the RJ45 port on the communication board
as shown in
Figure 36
.
(1)
The connection does not support RX/TX polarity change. Supporting crossover Ethernet cables depends on the switch
capabilities.
Chapter 6: Setting Up Communication 75
Three Phase Inverter with Synergy Technology Installation MAN-01-00401-1.5