SE33.3k SetApp Enabled Manual
Table Of Contents
- Disclaimers
- Support and Contact Information
- Revision History
- Contents
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimizers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Commissioning the Installation
- Chapter 6: User Interface
- Chapter 7: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Mechanical Specifications
- Appendix C: External Fan Maintenance and Replacement
- Appendix D: Replacing and Adding System Components
- Appendix E: Determining the Circuit Breaker Size
- Technical Specifications - Single Phase Inverters (North America)
- Technical Specifications - Three Phase Inverters (North America)
Chapter 7: Setting Up Communication
The inverter sends the following information to the monitoring platform:
Power optimizer information received via the DC power lines (the PV output
circuit).
Inverter information
Information of any other connected devices.
This chapter describes setting up communication between:
The inverter and the monitoring platform through the Internet (wired/ wireless),
or through a cellular connection.
Multiple inverters for a master/slave configuration.
Communication setup is not required for power harvesting, however it is needed for
using the monitoring platform.
CAUTION!
When connecting the communication cables, make sure that the ON/OFF
switch on the Safety Switch is turned OFF, and the AC is turned OFF.
When configuring the communication parameters, make sure that the ON/OFF
switch on the Safety Switch is OFF, and the AC is turned ON.
ATTENTION!
Lors de la connexion des câbles de communication, assurez-vous que
l'interrupteur MARCHE/ARRÊT à la base de l'onduleur soit en position ARRÊT,
et le CA est en position ARRÊT. Lors de la configuration des paramètres de
communication, assurez-vous que l'interrupteur MARCHE/ARRÊT soit en
position ARRÊT, et le CA est en position MARCHE.
Communication Options
The following types of communication can be used to transfer the monitored
information from the inverter to the monitoring platform.
Only communication products offered by SolarEdge are supported.
Always connect the communication options when the relevant devices are powered
down - Commercial Gateway, inverter, etc.
Ethernet
Ethernet is used for a LAN connection. For connection instructions refer to .
Chapter 7: Setting Up Communication 83
Three Phase System Installation Guide MAN-01-00002-4.3