To connect the Ethernet cable:
1. RemovetheinvertercoverasdescribedinRemovingtheInverterCoveronpage54.
2.
Openthecommunicationgland#1.
CAUTION!
The gland includes a rubber waterproof fitting, which should be used to ensure proper sealing.
ATTENTION!
Le cote interne du gland contient une rondelle qui doit être utilisée pour une bonne étancheïté.
3. Removetheplasticsealfromoneofthelargeopening.
4. RemovetherubberfittingfromtheglandandinserttheCAT5/6cablethroughtheglandandthrough
theglandopeningintheinverter.
5.
Pushthecableintothecutopeningoftherubberfitting.
Figure 30: Rubber fitting
CAT5/6standardcableshaveeightwires(fourtwistedpairs),asshowninthediagrambelow.Wirecolors
maydifferfromonecabletoanother.Youcanuseeitherwiringstandard,aslongasbothsidesofthe
cablehavethesamepin-outandcolor-coding.
RJ45 Pin #
Wire Color
1
10Base-T Signal
100Base-TX Signal
T568B T568A
1 White/Orange White/Green Transmit+
2 Orange Green Transmit-
3 White/Green White/Orange Receive+
4 Blue Blue Reserved
5 White/Blue White/Blue Reserved
6 Green Orange Received-
7 White/Brown White/Brown Reserved
8 Brown Brown Reserved
Figure 31: Standard cable wiring