Install Manual
Table Of Contents
- Disclaimers
- Support and Contact Information
- Revision History
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimisers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Activating, Commissioning and Configuring the System Using the Inverter SetApp
- Chapter 6: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Mechanical Specifications
- Appendix C: External Fan Maintenance and Replacement
- Appendix D: Replacing and Adding System Components
- Technical Specifications - Three Phase Inverters (North America)
EachpoweroptimizeralsotransmitsmoduleperformancedataovertheDCpowerlinetotheinverter.
Twotypesofpoweroptimizersareavailable:
l ModuleAdd-onpoweroptimizer–connectedtooneormoremodules
l Smartmodules-thepoweroptimizerisembeddedintoamodule
Inverter with Safety Switch
TheinverterefficientlyconvertsDCpowerfromthemodulesintoACpowerthatcanbefedintothemain
ACserviceofthesiteandfromtheretothegrid.Theinverteralsoreceivesthemonitoringdatafromeach
poweroptimizerandtransmitsittoacentralserver(themonitoringplatform;requiresInternet
connection).
TheSafetySwitchhasamanuallyoperatedswitchfordisconnectingtheDCpowerofaSolarEdgesystem.
TheSafetySwitchislocatedbelowtheinverterandisconnectedtotheinverterwithACandDCwires.
Monitoring Platform
Themonitoringplatformenablesmonitoringthetechnicalandfinancialperformanceofoneormore
SolarEdgesites.Itprovidespastandpresentinformationonthesystemperformancebothatthesystem
andmodulelevels.
Supported ACGrids
Figure 2: AC grids supported by SolarEdge three phase inverters
NOTE
Grid support depends on the inverter model. Some three phase inverters support the 208V 3-wire grid.
Refer to Setting the Inverter to Support 208V 3-wire Grid on page 34.
-Three Phase System Installation Guide MAN-01-00527-1.1
12
Inverter with Safety Switch